Auto Adjust Time

3-9
Auto Adjust Time
SNTP Server Setup
74
For details, refer to SECTION 3 Mail Receive Function in the Operation Man-
ual Construction of Applications.
Item
Obtain clock
If this option is selected, the CPU Unit's clock is set to
data from SNTP
the time at the SNTP server's clock.
server
The clock can be changed only for the CPU Unit to
which the Ethernet Unit is mounted.
Auto Adjustment Set the time at which the SNTP server is to be
accessed to synchronize the clocks.
When the time that is set here arrives, the SNTP
server is accessed and the CPU Unit clock is
adjusted to match the SNTP server clock.
Designation
Select whether the SNTP server used for automatic
Method
clock adjustment is to be specified by IP address or
by host domain name (i.e., by host name).
IP Address
Set the IP address for the SNTP server that is to be
used for automatic clock adjustment.
This setting is enabled only when server specification
by IP address has been selected.
Host Name
Set the host domain name (i.e., the host name) for
the SNTP server that is to be used for automatic
clock adjustment.
This setting is enabled only when server specification
by host name has been selected.
Port No.
Set the port number for connecting to the SNTP
server that is to be used for automatic clock adjust-
ment. This setting does not normally need to be
changed.
Contents
Section 3-9
Default
Not
checked
0:0:0
IP Address
0.0.0.0
None
0
(Number
123 is
used.)