Peripheral Rs-422/485 Port Communications Settings - Omron 3G3MV-P10CDT-E User Manual

Programmable controller option board
Hide thumbs Also See for 3G3MV-P10CDT-E:
Table of Contents

Advertisement

Communication, Counter and Pulse
12 to 15
Word(s)
Bit(s)
DM 6649
00 to 07
08 to 15

4-1-2 Peripheral RS-422/485 Port Communications Settings

Word(s)
Bit(s)
DM 6650
00 to 03
04 to 11
12 to 15
DM 6651
00 to 07
08 to 15
40
End code selection for no-protocol communications
0: Disables end code; 1: Enables end code in DM 6649; 2: Sets end code of CR, LF.
(Any other setting disables the end code, causes a non-fatal error, and turns ON AR 1302.)
Start code (00 to FF)
(This setting is valid only when bits 8 to 11 of DM 6648 are set to 1.)
When bits 12 to 15 of DM 6648 set to 0:
Sets the number of bytes to receive. (00: 256 bytes; 01 to FF: 1 to 255 bytes)
When bits 12 to 15 of DM 6648 set to 1:
Sets the end code. (00 to FF)
The following settings are effective after transfer to the PLC.
If the 3G3MV-P10CDT Unit's Communications Switch is ON, communica-
tions through the peripheral port are governed by the default settings (all 0)
regardless of the settings in DM 6650 through DM 6654.
The 3G3MV-P10CDT's Communications Switch setting has no effect on
communications with a Programming Console connected to the peripheral
port or Support Software set for peripheral bus communications. The
3G3MV-P10CDT Unit will auto-detect either Programming Device and auto-
matically establish communications.
Port settings
0: Standard (1 start bit, 7 data bits, even parity, 2 stop bits, 9,600 bps), Host Link unit
number: 0
1: Settings in DM 6651
(Any other setting will cause a non-fatal error and AR 1302 will turn ON.)
Not used.
Communications mode
0: Host Link or peripheral bus; 1: No-protocol
(Any other setting causes a non-fatal error and turns ON AR 1302.)
Baud rate
00: 1,200 bps; 01: 2,400 bps; 02: 4,800 bps; 03: 9,600 bps; 04: 19,200 bps
Frame format
Start bits
00:
1 bit
01:
1 bit
02:
1 bit
03:
1 bit
04:
1 bit
05:
1 bit
06:
1 bit
07:
1 bit
08:
1 bit
09:
1 bit
10:
1 bit
11:
1 bit
(Any other setting specifies standard settings (1 start bit, 7 data bits; even parity, 2 stop
bits, 9,600 bps), causes a non-fatal error, and turns ON AR 1302.)
Function
Function
Data bits
Stop bits
7 bits
1 bit
7 bits
1 bit
7 bits
1 bit
7 bits
2 bits
7 bits
2 bits
7 bits
2 bits
8 bits
1 bit
8 bits
1 bit
8 bits
1 bit
8 bits
2 bits
8 bits
2 bits
8 bits
2 bits
SECTION 4
Parity
Even
Odd
None
Even
Odd
None
Even
Odd
None
Even
Odd
None

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

3g3mv-p10cdt3-e

Table of Contents