140 W HFB+PAG2S Solution Board (REF_140W_HFB_PAG2S) user
guide
Quick steps to demo
6
Quick steps to demo
The following are the quick steps to set up and start the 140 W EPR USB PD Solution Board. This test uses
pre-configured PDOs.
1. Connect the 140 W Solution Board input to the AC terminal of the power meter (which must be connected to
the programmable AC supply beforehand), as shown in
2. Connect a USB PD tester or a power adapter tester (PAT) to the port and ensure that the USB PD tester gets
a successful Power Delivery contact, as shown in
3. Connect the electronic load at the PAT tester load terminal, as shown in
4. Select the desired voltage on the PAT UI and ramp up the load on the electronic load.
User guide
Figure 8.
Figure 9.
Figure
16
8.
002-38685 Rev. *A
2024-01-29
Need help?
Do you have a question about the REF 140W HFB PAG2S and is the answer not in the manual?