2. In the Swap monitor Device pane, enter the MIN or
serial number of the replacement device in the MIN#/
MONITOR ID text box.
3. Click the Search button.
4. In the Replacement monitor dropdown list, select
the unit you wish to replace the current unit with. The
screen displays the location of the selected unit. Any
differences between the unit types will be highlighted in
red to insure the correct unit type is being swapped in
or out.
IMPORTANT: If there are multiple choices to select from, be sure to
choose the correct tank number.
5. Click the Swap button.
The new monitor will now be associated with the cur-
rent tank.
NOTE: The tank name of the unit that was replaced will
be renamed with the prefix "was[space]."
9.3.6 Tank Calibration
When the onsite installer presses the Start button on
the monitor, all tank data will be sent to the BrightTEK
application. BrightTEK calculates tank inventory levels
based on data received from the monitor as well as data
provided by the system administrator in the Tank Setup
screen during the previous procedure.
The onsite installer must provide the system administra-
tor with a current level reading. Occasionally, the onsite
reading might not match the application's calculated
inventory level. If this is the case, the system adminis-
trator will need to adjust the "Sensor Offset" field for
integrated DP sensor models to add a positive or nega-
tive offset to all future readings.