4.5.6 Analog Scaling

Overview
This function allows you to scale analog current output or analog voltage output to any value.
By setting optional two points as measured value "A" and measured value "B", the values of
those optional points can be scaled to analog current output "a" and "b" or analog voltage
output "a" and "b". Analog output is produced by the scaling set in Analog Output.
● When "OFF" is selected in Analog Output, Analog scaling will not be displayed on the Setting
mode selection screen.
Setting method
The setting range and default value are shown in the following table. Note that the listed values
vary depending on models.
Item
Value A
Value B
Item
(Note 1)
Current a
(Note 1)
Current b
WUME-HLG2AN-2
Display section Distance type
30 mm
50 mm
85 mm
120 mm
250 mm
30 mm
50 mm
85 mm
120 mm
250 mm
Display section Setting range (mA)
4.000 to 20.000
Set value (mm)
-9.5000 to +9.5000
-95.000 to +95.000
-950.00 to +950.00
-9.5000 to +9.5000
-95.000 to +95.000
-950.00 to +950.00
Default value (mA)
4.000
20.000
4.5 Output Setting
Default value
(mm)
-5.0000
-10.000
-20.000
-30.000
-150.00
+5.0000
+10.000
+20.000
+30.000
+150.00