4.9 1 point/2 points/3 points Teaching

Overview
This method is used to set the HIGH set value and LOW set value using one or more sensing
objects.
● When performing teaching, it is necessary to set a teaching type in advance.
For details on setting the teaching type, refer to
● In the following case, teaching cannot be started.
• Hold mode is set to other than "None (Normal mode)".
● In the following cases, teaching will fail.
• Alarm state
• Indeterminate state
• The measured value is +OVER or -OVER displayed.
• Hold state (In this case, the state changes to indeterminate state after execution of
teaching.)
• When the measured value is the same at multiple points
• When the calculated HIGH set value / LOW set value does not meet "(HIGH set value -
LOW set value) > hysteresis × 2"
● The HIGH and LOW set values saved in teaching are set according to the setting resolution of
the product, where any numbers less than the resolution are internally processed as 0.
Settings
1 point teaching
2 points teaching
3 points teaching
WUME-HLG2AN-2
Operation
This method is to perform 1 point teaching on the distance from
the reference plane of a sensing object and to set HIGH set
value / LOW set value.
This method is to perform teaching on the reference planes of two
sensing objects and set the HIGH set value / LOW set value
based on the measured results.
This method is to perform teaching on the reference planes of
sensing objects 1, 2, and 3 and set the HIGH set value / LOW set
value based on the measured results.

4.9 1 point/2 points/3 points Teaching

"4.4.4 Teaching
Mode".
Reference page
"4.9.1 1 point
Teaching"
"4.9.2 2 points
Teaching"
"4.9.3 3 points
Teaching"
4-77