4.5 Output Setting

4.5.2 Output Delay Timer Selection

Overview
This setting is used to set the timing from ON to OFF or from OFF to ON for the measured
value judgment result (HIGH / GO/ LOW).
Set value
OFF (No timer)
On Delay
Off Delay
One Shot
Hold
● When the output delay timer or timer's time is changed during output delay operation, the
changed set value is reflected when the output is changed next time.
Setting method
● Hold down the <ENTER> key for 2 seconds on the setting screen, and the setting change is
suspended and the screen returns to the previous display.
4-42
Operation
No change is made in the timing for the measured value judgment result.
When the measured value judgment result is turned ON from OFF, the ON output is
delayed for the timer's time.
When the measured value judgment result is turned OFF from ON, the OFF output
is delayed for the timer's time.
When the measured value judgment result is turned ON from OFF, the ON output is
held for the timer's time and then OFF output is given.
The output signal is held for a period from when sensing is started to when the
measured value reset input is turned ON.