TROUBLESHOOTING
Continued
OBSERVED PROBLEIH
POSSIBLE CAUSE
REfiEDY
Burner(s)does not light after
Burner orifice is clogged
1. Clean burner orifice (see Cleaning
ODS/pilot is lit
2.
Burner orifice diameter is too small
and Maintenance, page 13) or
3.
inlet gas pressure is too low
replace burner orifice.
2. Replace burner orifice
3. Contact local natural gas company
Delayed ignition of burner(s)
1
. Manifold pressure is too low
1. Contact local natural gas company
2. Burner orifice is clogged
2. Clean burner (see Cleaning and
Maintenance, page 13) or replace
burner orifice
Burner backfiring during combustion
1. Burner
orifice
is clogged
damaged.
2. Burner damaged
3. Gas regulator defective
or
1. Clean burner orifice (see Cleaning
and
Maintenance, page 13) or
replace
2. Replace burner
3. Replace gas regulator
Burner Plaque(s) does not glow
1. Plaque damaged
2. Control knob set between locked
positions
3. Inlet gas pressure is too low
1. Replace burner
2. Turn control knob until It locks at
desired setting
3. Contact
local
natural
gas
company
Slight
smoke
or
odor during
Residues from manufacturing
1. Problem will stop after a few hours
initial operation
processes
of operation
Heater produces a clicking/ticking
^
Metal expanding while heating or
1. This is common with most heaters,
noise just after burner is lit or
contracting while cooling
If noise is excessive, contact
shut off
qualified service person
White powder residue forming
within burner box or on adjacent
walls or furniture
1. When
heated,
vapors
from
furniture polish, wax, carpet
cleaners,
etc. turn into white
powder residue
1. Turn
heater
off
when
using
furniture
polish,
wax.
carpet
cleaner or similar products.
PRO-COM
OWNER'S
MANUAL
INFRARED VENT-FREE GAS SPACE HEATER
15
ML062-11

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MN180HPA and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Mn300hpaMn180tpaMn300tpa

Table of Contents