5. Insert the cable into the sensor through the
cable entry
6. Lift the opening levers of the terminals with
a screwdriver (see following illustration)
7. Insert the wire ends into the open terminals
according to the wiring plan
Abb. 24: Connection steps 6 and 7
8. Press down the opening levers of the
terminals, you will hear the terminal spring
closing
9. Check the hold of the wires in the terminals
by lightly pulling on them
10. Tighten the compression nut of the cable
entry gland. The seal ring must completely
encircle the cable
11. Screw the housing lid back on
The electrical connection is finished.
4.3

Wiring plan

4...20mA
+ -
1 2
1
Abb. 25: Wiring plan, single chamber housing
1
Voltage supply and signal output
4.4

Switch-on phase

Switch-on phase
After connecting VEGASON S 62 to power sup-
ply or after a voltage recurrence, the instrument
carries out a self-check for approx. 30 seconds:
Internal check of the electronics
Indication of the instrument type, the firm-
ware as well as the sensor TAGs (sensor
designation)
VEGASON S 62 •
Display

5 Set up with the display and adjustment module

Output signal jumps briefly (approx. 10
seconds) to the set fault current
Then the corresponding current is output to the
cable. The value corresponds to the actual level
as well as the settings already carried out, e.g.
factory setting.
5
Set up with the display and
adjustment module
5.1

Short description

Function/Configuration
The display and adjustment module is used
for measured value indication, adjustment and
diagnosis.
Note:
You can find detailed information on
adjustment in the operating instructions
manual "Display and adjustment mo-
dule".
5.2
Insert display and adjust-
ment module
Mount/dismount display and adjustment
module
The display and adjustment module can be
inserted into the sensor and removed again
at any time. It is not necessary to interrupt the
voltage supply.
Proceed as follows:
1. Unscrew the housing lid
2. Place the display and adjustment module
in the desired position on the electronics
(you can choose any one of four different
positions - each displaced by 90°)
3. Press the display and adjustment module
onto the electronics and turn it to the right
until it snaps in
4. Screw housing lid with inspection window
tightly back on
Disassembly is carried out in reverse order.
25