Wiring Plan - Single Chamber Housing - Vega VEGACAP 69 Operating Instructions Manual

Capacitive double rod electrode for level detection
Table of Contents

Advertisement

Housing overview
VEGACAP 69 • Two-wire
Fig. 6: Connection steps 5 and 6
6. Insert the wire ends into the open terminals according to the wir-
ing plan
7. Press down the opening levers of the terminals, you will hear the
terminal spring closing
8. Check the hold of the wires in the terminals by lightly pulling on
them
9. Tighten the compression nut of the cable entry gland. The seal
ring must completely encircle the cable
10. If necessary, carry out a fresh adjustment
11. Screw the housing lid back on
The electrical connection is finished.
5.3

Wiring plan - single chamber housing

4
1
Fig. 7: Material versions - single chamber housing
1
Plastic (not with dust-Ex)
2
Aluminium
3
Stainless steel
4
Filter element for pressure compensation or blind plug with version IP66/
IP68, 1 bar
5 Connecting to power supply
4
2
4
3
15