..C4-H Testing
Procedures..

3 Normal Directional Limit Test

Applicable Code – ASME A17.1/B44-19 section 3.25.1
The following procedure describes how to test for normal direction limit.
1. Enter a car call to the top or bottom terminal that is being tested by navigating to MAIN MENU |
DEBUG |ENTER CAR CALLS.
2. Toggle the NORMAL/INSPECTION switch to INSPECTION.
3. Run the car past the door zone of the terminal under inspection by pressing:
-
Enable and Up – If testing the upper terminal
-
Enable and Down – If testing the lower terminal
4. Verify the display shows a Normal Limit Reached alarm.
5. Recycle the MR board to clear the alarm.
6. Toggle the NORMAL/INSPECTION switch to Normal and the car relevels.

4 Releveling with In-Car Stop Switch

Applicable Code – ASME A17.1/B44-19 sections 2.26.2.21
The following procedure describes how to test for releveling with the In-Car Stop switch.
1. Navigate to MAIN MENU | SETUP | FLOORS | ENABLE RELEVELING and select ON.
2. Stop the car in the door zone and turn on In-Car Stop switch.
3. Verify an IC Stop fault displays.
4. Bleed out valve SLOWLY to allow car to drop out of dead zone but NOT out of door zone.
5. Turn off In-Car Stop switch and the car relevels within a few seconds.

5 Redundancy

5.1 Safety Inputs

Applicable Code – ASME A17.1/B44-19 section 2.26.9.3
• Testing Notes – The following testing notes are:
-
Software/Hardware electronic protective devices are monitored by redundant board inputs.
-
The redundant inputs are constantly compared with one another to verify proper operation of
the input circuitry. If the inputs are not in the same state, a Redundancy fault is latched, and
the car goes out of service.