LCD Operator
oPr
Oper Disconnect
Cause
Option is not properly connected to the unit.
<1> Display will vary depending on operation status.
YASKAWA ELECTRIC TOBP C730600 29G 1000-Series Option JVOP-180 Installation Manual
LED Operator
(V1000)
LCD Operator Option Connection Fault
Data should appear on the LED operator. By reconnecting the
option to the unit, data should also appear on option display.
An oPr fault will occur when both of the following conditions are
oPr
true:
Output is interrupted when the option is disconnected (o2-06 = 1).
The Run command is assigned to the option (b1-02/b1-16 = 0 and
LOCAL is selected).
• Check the connection between the option and the unit.
• Replace the cable if damaged.
• Turn off the unit input power and disconnect the option.
Reconnect the option and reapply unit input power.
8 Option Fault Diagnostics
Description
Possible Solution