COMSPHERE 6800 Series Nework Management System
Changing an Embedded or Synchronous SDL Configuration
You can change an embedded or a synchronous SDL configuration using the procedure below.
1. Execute the Change SDL Configuration (chsdlc) command.
2. Enter the node and the link. A time slot summary for the specified node and link is
3. Choose a time slot to configure as either embedded SDL or synchronous SDL by selecting
4. For synchronous SDLs, skip to Step 7. To configure a time slot for an embedded SDL,
5. Make sure that no other embedded SDL is already configured on the link. If one is, and
1-28
If you need to change a synchronous SDL channel from an SDL
configuration to a standard synchronous data channel configuration,
the Change SDL Configuration ( chsdlc ) command must first be
executed to take the synchronous SDL out-of-service. Then you can
configure the channel appropriately through the Change Channel
Configuration ( chcc ) command.
displayed.
yes in the desired time slot. Only one embedded SDL can be configured per link, but
multiple synchronous SDLs are permitted.
perform Steps 5 and 6.
you need to change the embedded SDL to a different time slot, first you must take the
existing one out-of-service.
Depending on your network connectivity, you can disrupt or
lose diagnostic connectivity to other nodes in your network
when you take an existing embedded SDL out-of-service.
To take the existing embedded SDL out-of-service, select its time slot, then
PRESS: GO
and on the succeeding form, change the state of the SDL to out-of-service. When the
command has been successfully executed, perform the Change SDL Configuration (chsdlc)
command again.
August 1994
NOTE
CAUTION
6800-A2-GB21-10