Table C-1. NMS 6700 Device MIB Objects (10 of 17)
Object
devCirQualRetrainsValidity
(devCirQual 25)
devCirQualRetrains
(devCirQual 26)
devCirQualBlownStartupsValidity
(devCirQual 27)
devCirQualBlownStartups
(devCirQual 28)
devCirQualGainHitsValidity
(devCirQual 29)
devCirQualGainHits
(devCirQual 30)
6700-A2-GB20-30
Description
Validity of the object
devCirQualRetrains.
The setting not-available-yet(6)
is also used if circuit quality is
not supported by the device
type.
Circuit quality retrains. Integer
value represents the number of
retrain events during the last 15
minutes.
Validity of the object
devCirQualBlownStartups.
The setting not-available-yet(6)
is also used if circuit quality is
not supported by the device
type.
Circuit quality blown startups.
Validity of the object
devCirQualGainHits.
The setting not-available-yet(6)
is also used if circuit quality is
not supported by the device
type.
Circuit quality gain hits.
September 1998
NMS Device MIB Specifications
Setting/Contents
valid(1)
valid-greater-than(2)
valid-less-than(3)
not-valid-for-modulation-mode(4)
not-valid-for-multipoint-mode(5)
not-available-yet(6)
count-overflow(7)
not-used(8)
Supported as read-only.
Possible range is 0 to 4095.
Supported as read-only.
valid(1)
valid-greater-than(2)
valid-less-than(3)
not-valid-for-modulation-mode(4)
not-valid-for-multipoint-mode(5)
not-available-yet(6)
count-overflow(7)
not-used(8)
Supported as read-only.
Supported as read-only.
valid(1)
valid-greater-than(2)
valid-less-than(3)
not-valid-for-modulation-mode(4)
not-valid-for-multipoint-mode(5)
not-available-yet(6)
count-overflow(7)
not-used(8)
Supported as read-only.
Integer value represents the number of
gain hit events during last 15 minutes.
Possible range is 0 to 4095.
Supported as read-only.
C-11