socket by the cable. Protect the
cable from heat, oil and sharp
edges.
• Do not carry or fi x the equip-
ment by the cable.
• Use only extension cables that
are protected from spray water
and designed for outdoor use.
Always fully unroll a cable drum
before use. Check the cable for
damage.
• Disconnect the mains plug from
the socket before all work on
the equipment, in case of leaks
in the water system, during
work breaks, and when not in
use.
• The cross-section of extension
cords must be no smaller than
rubber hose lines with the des-
ignation H05RN-F. The line
must be at least 10 m long. The
fl exible lead cross-section of
the extension cord must at least
2.5 mm
.
2

Operational start-up

Assembly

To screw-on the adaptor:
1. Screw the angle adaptor (11) and the
hose adaptor (9) onto the pump outlet
(4).
Fitting height adjustment for
fl oat switch:
2. Slide the fl oat switch height adjustment
(6) over the fl oat switch guide (8) next
to the handle (1).
24
Connection of the
pressure line
The installation of the submersible water
pump is implemented either
- with fi xed pipe or
- with fl exible hose line.
• If using a ½" hose, attach the hose
over the pump's hose connection (9)
and fasten it with a hose clamp if nec-
essary.
• To use a ¾", 1" or 1½" hose, cut off
the connection above and attach the
hose over the correct connection (fi xing
with a hose clamp).
• For the use of a tap connector with
internal thread (G 1") for connecting
external hose connection systems, cut
the top three connections off directly
over the G 1" threaded pipe.
• Connect a tap connector with internal
thread (G 1 ½") directly to the angle
adapter (11).
The measurement of the maximum
performance data takes place un-
der optimal conditions, such as a straight,
direct exit. The angle adaptor (11) and the
backfl ow stopper (
put.
To increase pump output, the backfl ow
stopper (
10) may be taken out of the
angle adaptor (11) (see "replacing back-
fl ow stopper"). This is particularly recom-
mended for hose connections smaller than
1". Please bear in mind that the water may
then fl ow back during pumping, or in the
event of a power cut.

To erect/suspend

The pump can be erected or sus-
pended in the water.
10) may reduce out-