• Only connect the device to a so-
cket with a residual current de-
vice (RCD) with a rated residual
current of no more than 30 mA;
fuse must be at least 10 amps.
• Check the device, power cables
and mains plug for damage be-
fore each use. Defective power
cables must not be repaired.
They must be replaced. Ensure
that damage to your device is
repaired by a specialist.
• If the connection cable of this
device is damaged, it must be
replaced by the manufacturer
or their customer service or by
a similarly qualified person in
order to avoid hazards.
• Do not use the mains cable to
pull the plug from the socket.
Protect the mains cable from
heat, oil and sharp edges.
• Do not carry or secure the de-
vice by its mains cable.
• Use only extension cables that
are splash-proof and designed
for outdoor use. Always roll out
the cable reel completely before
use. Check the mains cable for
damages.
• Remove the plug from the mains
socket before carrying out work
on the device, during work bre-
aks and when not in use.
• Mains connection cables must
not have a cross-section that
is smaller than those of rubber
hoses with the designation
H07RN-F. The strand cross-sec-
tion of the extension cable must
be at least 2.5 mm
18
2
.

Initial start-up

Assembly

If you would like to permanently install
the domestic water system, screw it to
the base. A screw connection with a
fastening plate also prevents the device
from slipping.
When doing so, ensure free access to
the drain screw (10).
If you use the domestic water sys-
tem in the house, you must seal
all screw connections with sealing
tape.

Mains connection

The domestic water system you have
purchased is already equipped with a
safety plug. The domestic water system is
intended for connection to a 230 V~ 50
Hz earthed socket.

Setting up

Place the device on a solid, horizontal
base which is also safe from flooding.
In principle, place the domestic water
system higher than the water surface
out of which you would like to pump.
If this is not possible, install a vacuum
resistant shut-off unit between the de-
vice and the suction line (available at
specialised traders or DIY stores).
The pressure accumulator (7) must
show an air pressure of 0.15 MPa
(1.5 bar) in an unused condition.
Check the air pressure before the
initial start-up.