Manual Mode; Operational Start-Up; Cleaning/Maintenance/Storage - Parkside PTPS 1100 A1 Translation Of The Original Instructions

Submersible dirty water pump
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 17
GB
IE
Check this by placing the pump
into a vessel filled with water
and lift the float switch
(
3) carefully by hand and
then lower it again. In this case,
you can see whether the pump
switches on and off.
- Also ensure that the separa-
tion distance between the float
switch (
switch height adjustment (
is not too small. In the case of a
separation distance which is too
small, trouble-free functioning
cannot be guaranteed.
- During the adjustment of the
float switch (
the float switch does not contact
the floor before the pump switch-
es off.
The pump run dry if too long a float
switch cable (
particularly if the float switch height
adjustment (
(see „Initial Operation").

Manual mode

In manual mode, the pump does not switch
off automatically, as the float switch (
is bypassed.
Position the float switch (3) vertical-
ly upward in the float switch height
adjustment (2).
Monitor the pump constantly when
in manual mode. Switch the pump
off immediately (disconnect from
the mains) if no more water is be-
ing pumped. There is a risk of dam-
age if the pump runs dry.
24
3) head and the float
2)
3), ensure that
12) is chosen,
2) is not installed

Operational start-up

• Check that the pump is standing
firmly on the bottom of the shaft
or hung up safely.
• Place the pump on a brick and
not on a shaft floor, if applica-
ble. This prevents damage to the
pump if the shaft floor is soiled.
• Check whether the pressure line
has been attached correctly and
the unused pump outlet is fully
closed.
• Avoid that the pump runs dry.
Regularly check the function
of the float switch. In case of
non-observance or if the pump
runs dry, guarantee and liability
claims are invalidated.
• Check that the electrical connec-
tion is 230 V ~50 Hz
• Check the proper status of the
electrical plug socket and make
sure that the plug socket is suf-
ficiently fused (at least 6 A, RCD
switch). Insert the pump plug into
the plug socket and the pump is
ready for operation.
• Make sure that moisture or water
never come in contact with the
3)
mains connection. There is a risk
of electrocution.
Cleaning/Maintenance/
Storage
Clean and maintain your equipment regu-
larly. This will guarantee its performance
and long durability.
Ask our service centre to carry out
any work that is not described in
these instructions. Use only original
parts.