OPERATING THE DEVICE

The device allows for connecting switch to the S1 and S2 terminals.
These may be monostable or bistable switches.
Switch buttons are responsible for managing the blind's movement.
Description:
– Switch connected to the S1 terminal
– Switch connected to the S2 terminal
General tips:
You can perform/stop movement or change direction using switch/es
If you set flowerpot protection option the down movement action will perform only to defined level
If you control only a venetian blind position (not slats rotation) the slats will back to their previous position (in aperture level 0-95%).
Monostable switches – click to move
Example of the switch design:
10
Monostable switches - click to move
Parameter:
20.
Value:
0
Parameter:
151. Roller blind, Awning, Pergola or Curtain
Description:
1×click
1×click
2×click
Hold
Hold
Available values:
0
Parameter:
151. Venetian blind
Description:
1×click
1×click
2×click
Hold
Hold
Available values:
1 or 2
Favorite position – available
switch
- Initiate up movement to the limit position
Next click - stop
switch
- Initiate down movement to the limit position
or
switch - Favorite position
- Up movement until release
- Down movement until release
switch
- Initiate up movement to the limit position
Next click - stop
switch
- Initiate down movement to the limit position
or
switch - Favorite position
- Turning slats up until release
- Turning slats down until release