13
ADVANCED PARAMETERS
The device allows customizing its operation to user's needs using configurable parameters.
The settings can be adjusted via the Z-Wave controller to which the device is added. The way of adjusting them might differ depending on
the controller.
In the NICE interface device configuration is available as a simple set of options in the Advanced Settings section.
To configure the device:
1.
Go to Settings
.
2.
Go to Devices.
3.
Select the relevant device from the list.
4.
Select the Advanced or Parameters tab.
5.
Select and change parameter.
6.
Save your changes.
Advanced parameters
Parameter:
20. Switch type
Description:
This parameter determines with which switches types and in which mode the S1 and S2 inputs
operate.
Available settings:
0 - Monostable switches – click to move
1 - Monostable switches – hold to move
2 - Single monostable switch
3 - Bistable switches
4 - Single bistable switch
5 - Three-state switch
Default setting:
0 (default value)
Parameter:
24. Buttons orientation
Description:
This parameter allows reversing the operation of the buttons.
Available settings:
0 – default (1st button UP, 2nd button DOWN)
1 – reversed (1st button DOWN, 2nd button UP)
Default setting:
0 (default value)
Parameter:
25. Outputs orientation
Description:
This parameter allows reversing the operation of O1 and O2 without changing the wiring (e.g. in case
of invalid motor connection).
Available settings:
0 - default (O1 – UP, O2 – DOWN)
1 - reversed (O1 – DOWN, O2 – UP)
Default setting:
0 (default value)
Parameter:
40. First button – scenes sent
Description:
This parameter determines which actions result in sending scene IDs assigned to them. Values can
be combined (e.g. 1+2=3 means that scenes for single and double click are sent).
Enabling scenes for triple click disables entering the device in learn mode by triple clicking.
Available settings:
0 - No scene active
1 – Key pressed 1 time
2 – Key pressed 2 times
4 – Key pressed 3 times
8 – Key hold down and key released
Default setting:
15 (All scenes active)
Parameter size:
1 [byte]
Parameter size:
1 [byte]
Parameter size:
1 [byte]
Parameter size:
1 [byte]