INSTALLATION

Connecting the device in a manner inconsistent with this manual may cause risk to health, life or material damage.
Before the installation
Do not power the device before fully assembling it in the mounting box,
Connect only in accordance with one of the diagram,
Install only in flush mounting boxes compliant with a relevant national safety standards and with depth no less than 60mm,
Do not connect heating devices,
Do not connect SELV or PELV circuits,
Electrical switches used in installation should be compliant with the relevant safety standards,
Length of wires used to connect the control switch should not exceed 20m,
Connect roller blind AC motors with electronic or mechanical limit switches only.
Notes for the diagrams:
O1 - 1st output terminal for shutter motor
O2 - 2nd output terminal for shutter motor
S1 - terminal for 1st switch (used to add/remove the device)
S2 - terminal for 2nd switch (used to add/remove the device)
N - terminals for the neutral lead (connected internally)
L - terminals for live lead (connected internally)
PROG - service button (used to add/remove the device and navigate the menu)
ATTENTION ! Proper wiring and wire removal guidelines
Place wires ONLY into terminal slot(s) of the device.
To remove any wires, press the release button, located over the slot(s)
Installation
1.
Switch off the mains voltage (disable the fuse).
2.
Open the wall switch box.
3.
Connect with the following diagram.
Wiring diagram –
connection with AC motor
PE
L
N
N
NICE Roll-Control2
4.
Verify if the device is connected correctly.
5.
Arrange the device in a wall switch box.
6.
Close the wall switch box.
7.
Switch on the mains voltage.
Note:
If you are using Yubii Home, HC3L or HC3 Hub, you don't have to concern about connecting the directions correctly.
You can change the directions in the the wizzard and device settings in the mobile app.
To connect external switch/ switches use supplied jumper wires if necessary.