Cutout in
adaptor
properly
aligned to
probe bracket
Probe Bracket
Diagram 2A
10. Fully insert the probe into the probe bracket
as shown. See diagram 3.
Diagram 3
11. Install the unit by first setting the rear of the
unit into the fireplace. See Diagram 4. Ensure
that the unit is centered in the existing fireplace
and lined up with the flue adaptor.
Diagram 4
12. Slide the unit back until the flue adaptor is
slightly engaged. At this point it is recom-
mended to level the unit. This will keep the
adaptor from binding.
13. Insert the provided pull rod through the hole in
the top center of the unit. Secure the threaded
end into the flue adaptor as shown in diagram
5. While sliding the unit into place pull on the
rod to ensure that the flue adaptor is properly
engaged. See Diagram 6. Double check the
adaptor is seated properly and the pull rod in
the firebox, locate the two holes lined up to
the two holes on the adaptor.
Pull Rod
Diagram 5
Pull Rod in place
Diagram 6
14. To complete the install, use the two bolts,
washers and lock washers removed in step
6 and install them, tighten down using the
1/2" socket to ensure the adapter is positively
secured to the unit. Once completed remove
pull rod and place away for future re-install.
Diagram 7
installation
15. When re-installing flue collar after it has been
attached to the flex, be careful to guide the
bypass arm through front above the door. This
can only be guided through firebox opening.
Opening
for bypass rod
Guide the bypass
rod through open-
ing inside firebox
Diagram 8
16. Repeat steps 5-1 to complete install.
Regency I2500-1 Wood Fireplace Insert
|