ATEX Information

1. Standards covered:
EN IEC 60079-0:2018
EN IEC 60079-7:2015 + A1:2018
EN IEC 60079-15:2019
2. Conductors suitable for Rated Cable Temperature ≥ 120°C
3. Ambient Range : -40°C ≤ Tamb ≤ 75°C (with -T model)
Ambient Range : -20°C ≤ Tamb ≤ 60°C (without -T model)
WARNING – DO NOT SEPARATE WHEN ENERGIZED
Rated Cable Temp ≥ 120°C

Conditions for Safe Use

1. The equipment shall only be used in an area of at least pollution
degree 2, as defined in EN IEC 60664-1.
2. The equipment shall be installed in an enclosure that provides a
minimum ingress protection of IP54, in accordance with
EN IEC 60079-0.
Moxa Inc.
No. 1111, Heping Rd., Bade Dist., Taoyuan City 334004, Taiwan
Ex ec IIC T4 Gc
UL 20 ATEX 2412X