NO
C
SSR
R
S
TECHNICAL SPECIFICATION
TC-1X
Model
Size
76(H)X27(W)X85(D)mm
Input
J,K
Temperature
J:0to400° C/K:0to500° C
Range
ControlAction
1Relay||1S.S.R.1C/Ocontact,230VAC,5A
Output
PowerSupply
Operating
Temperature
Relative
Upto95%RHNonCondensing
Humidity
Accuracy
Communication
Format
MECHANICAL INSTALLATION
Outline Dimension (mm)
27.5
27.5
-
NO
C
+
SSR
-
NO
C
+
SSR
76
76
TC2X
R
S
R
S
TR
TR
TR
TR
TR
TR
TR
TR
TR
WINDOW
WINDOW
WINDOW
WINDOW
WINDOW
WINDOW
WINDOW
WINDOW
WINDOW
TR
TR
TR
TR
TR
TR
TR
TR
TR
WINDOW
WINDOW
WINDOW
WINDOW
WINDOW
WINDOW
WINDOW
WINDOW
WINDOW
E
E
Din rail Mounting Distance
52.5mm-2.067inches
25mm
BlindTemperatureController
TC-1X & TC- 2X
-
-
+
SSR
NO
C
TC2X
R
S
E
E
TC-2X
PID/TP/ON-OFF
24VDC
0° CTo55° C
1%ofFSD
RS-485(Modbus)
RTU/ASCII
Panel Cutout
Dimension (mm)
85
+24
GND
D-
D+
76
www.multispanindia.com
MECHANICAL INSTALLATION GUIDELINES
1. Prepare the panel cutout with proper dimensions as shown above.
2. Fit the unit into the panel with the help of clamp given.
3.The equipment in its installed state must not come in close proximity
to any heating source, caustic vapors, oils steam, or other unwanted
process byproducts.
4. Use the specified size of crimp terminal (M3.5 screws) to wire the
terminal block. Tightening the screws on the terminal block using the
tightening torque of the range of 1.2 N.m.
5. Do not connect anything to unused terminals.
1. The equipment should be cleaned regularly to avoid blockage
of ventilating parts.
2. Clean the equipment with a clean soft cloth. Do not use
isopropyl alcohol or any other cleaning agent.
3. Fusible resistor must not be replaced by operator.
0=OFF
1=ON
Time(Sec)
1
2
3
4
5
6
7
8
9
10
11
12
TERMINAL CONNECTION
+
-
NO
C
SSR
Relay ON/OFF
Switch
Connector
R
S
E
Earthing
Sensor:
Sensor:
'J'
0 To 400°C
'K'
0 To 500°C
Made in India
www.multispanindia.com
TC-1X
MAINTENANCE
Error
Auto
Main
Run
R
S
Tune
Blind
EverytimetheinstrumentisturnON,FollowingpatternwillbeLEDIndication
PowerONInstrument
0/
1
1 1 1 1 1
ALLLEDON
ThisLED
Continue
ON/OFF
0 0 0 0
0/
1
ThisLED
0=RTU
0=8 bit
0=1 bit
Continue
1=ASCIT
1=7 bit
1=2 bit
ON/OFF
0/
1
ThisLED
Continue
(AddressValueBinaryFormat)
ON/OFF
(e.g6=00000110,11=00001011)
odd
Even None 38400 19200 9600 4800 2400
0x06 0x10
0x04 0x3
W
!
All safety related codifications, symbols and instructions
that appear in this operating manual or on the equipment
must be strictly followed to ensure the safety of the operating
-
NO
C
+
SSR
personnel as well as the instrument.
If all the equipment is not handled in a manner specified
by the manufacturer, it might impair the protection provided
by the equipment.
Connector
Read complete instructions prior to installation
TC 2X
and operation of the unit.
R
S
WARNING : Risk of electric shock.
E
Earthing
1. This equipment, being built-in-type, normally becomes a part of main
'J'
0 To 400°C
control panel and in such case the terminals do not remain accessible to
'K'
0 To 500°C
the end user after installation and internal wiring.
2. Do not allow pieces of metal, wire clippings, or fine metallic fillings from
installation to enter the product or else it may lead to a safety hazard that
may in turn endanger life or cause electrical shock to the operator.
Made in India
3. Circuit breaker or mains switch must be installed between power source
and supply terminal to facilitate power 'ON' or 'OFF' function. However this
TC-2X
mains switch or circuit breaker must be installed at convenient place
normally accessible to the operator.
4. Use and store the instrument within the specified ambient temperature
and humidity ranges as mentioned in this manual.
WARNING GUIDELINES
WARNING : Risk of electric shock.
1. To prevent the risk of electric shock, power supply to the equipment must be
kept OFF while doing the wiring arrangement. Do not touch the terminals while
power is being supplied.
2. To reduce electro magnetic interference, use wire with adequate rating and
twists of the same of equal size shall be made with shortest connection.
3. Cable used for connection to power source, must have a cross section of
1mm or greater. These wires should have insulations capacity made of at least
1.5kV.
4. When extending the thermocouple lead wires, always use thermocouple
compensation wires for wiring for the RTD type, use a wiring material with a
small lead resistance (5 max per line) and no resistance differentials among
three wires should be present.
5. A better anti-noise effect can be expected by using standard power supply
cable for the instrument.
TX
RX
Sensor
Break
TC-1X/TC-2X
1
1
1
(InputFrame)
K
J
Float
Integer
R
(AllLedisOFF)
(AllLedisON)
SAFETY PRECAUTION
INSTALLATION GUIDELINES
Ω
Page -1