Batteries; Operating Principles - Leica GS18 User Manual

Hide thumbs Also See for GS18:
Table of Contents

Advertisement

4.2
4.2.1
First-time use/
charging batteries
Operation/discharging
36
Action
2.
Type in 192.168.253.2. The Web server is started. You will see the
home functions following:
Go to Work!
To select and start the Wake-up application.
Current Status
To access GNSS information of the GS as well as the instru-
ment firmware.
Instrument
To access configuration settings for the GS.
User
To upload and activate firmware, licence keys and lan-
guages.

Batteries

Operating Principles

The battery must be charged before using it the first time, because it is
delivered with an energy content as low as possible or might be in sleep
mode.
The permissible temperature range for charging is from 0 °C to +40 °C/
+32 °F to +104 °F. For optimal charging, we recommend charging the
batteries at a low ambient temperature of +10 °C to +20 °C/+50 °F to
+68 °F if possible
It is normal for the battery to become warm during charging. Using the
chargers recommended by Leica Geosystems, it is not possible to charge
the battery once the temperature is too high
For new batteries or batteries that have been stored for a long time
(> three months), it is effectual to make only one charge/discharge cycle
For Li-Ion batteries, a single discharging and charging cycle is sufficient.
We recommend carrying out the process when the battery capacity indic-
ated on the charger or on a Leica Geosystems product deviates signific-
antly from the actual battery capacity available.
The batteries can be operated from −20 °C to +55 °C/−4 °F to +131 °F.
Low operating temperatures reduce the capacity that can be drawn; high
operating temperatures reduce the service life of the battery.