9 Accessories

For further information see datasheet Accessories.
Description
Inlet and outlet path BSP thread, stainless steel for gauge mounting block
M12x1 cable connector, 4-pole socket (plastic) for self assembly
M12x1 cable connector, 5-pole socket (metal) for self assembly
Connection cable, M12x1, 5-pole socket - free ends, shielded, PUR
Connection cable, M12x1 5-pole socket - plug, shielded, PUR
Connection Cable M12x1 4-pole socket, angled 90°
Sealing plugs for the gauge mounting block
(for operating the pipeline without the sensing unit)
Gasket set for gauge mounting block with flanges

10 Technical Data

Measurands
Volume Flow (V'n)
Standard conditions
1)
Measuring range
in air at standard conditions
2)
Accuracy
in air @ 7 bar (102 psi) (abs) and 23 °C (73 °F)
Temperature dependency
Pressure dependency
Response time t
90
Sampling interval
1) For factory setting, see chapter 10.1 Factory Setting of Outputs for DN15 / DN20 / DN25 and
chapter 10.2 Factory settings of the outputs DN32 / DN40 / DN50.
2) The tolerance specifications include the uncertainty of the factory calibration with a coverage factor k=2 (2 x standard deviation).
The tolerance was calculated in accordance with EA-4/02 following the GUM (Guide to the Expression of Uncertainty in Measurement).
3) T he flow meter is factory adjusted at 7 bar (abs, 102 psi). Pressure compensation is valid for v = 10...120 m/s. Without entering the system
pressure into the EE741, the pressure dependency is ±0.5 % of the measured value / bar deviating from 7 bar.
Temperature (T)
Measuring range
Accuracy
@ 24 V DC, 20 °C (68 °F)
DN15 (1/2")
DN20 (3/4")
DN25 (1")
DN32 (1-1/4")
DN40 (1-1/2")
DN50 (2")
1.5 m (4.9 ft)
5 m (16.4 ft)
10 m (32.8 ft)
2 m (6.6 ft)
5 m (16.4 ft)
10 m (32.8 ft)
2 m (6.6 ft)
DN32 (1-1/4")
DN40 (1-1/2")
DN50 (2")
Factory setting according to DIN 1343
pn = 1 013.25 mbar (14.7 psi); Tn = 0 °C (32 °F), freely configurable via EE-PCS
3
DN15 (1/2")
0.2...76.3 m
/h
3
DN20 (3/4")
0.4...135.7 m
/h
DN25 (1")
3
0.6...212 m
/h
3
DN32 (1-1/4")
0.9...347.4 m
/h
3
DN40 (1-1/2")
1.4...542.8 m
/h
3
DN50 (2")
2.2...848.2 m
/h
±(3 % of measured value + 0.3 % of full scale)
±(0.25 % of measured value / °C deviating from 23 °C (73 °F))
Compensation by entering the system pressure using EE-PCS
<2 s
0.1 s
-20...+60 °C (-4...+140 °F)
±0.7 °C (±1.26 °F)
Code
HA070215
HA070220
HA070225
HA070232
HA070240
HA070250
HA010707
HA010708
HA010819
HA010820
HA010821
HA010816
HA010817
HA010818
HA010824
HA070204
HA074532
HA074540
HA074550
(0.12...44.88 SCFM)
(0.24...79.77 SCFM)
(0.36...124.71 SCFM)
(0.52...202.06 SCFM)
(0.81...315.71 SCFM)
(1.22...493.35 SCFM)
Inline Flow Sensor for Compressed Air and Gases | 30