5.1.1.

Switch and Pulse Outputs Internal Circuit

Switch and pulse outputs are NOT potential-free and include internal pull-down resistors (Fig. 16).
V+
GND
Fig. 16
S witch / pulse output
OUT 1
OUT 2
10k
10k
GND