Io-Link - E+E Elektronik EE741 User Manual

Inline flow sensor for compressed air and gases
Hide thumbs Also See for EE741:
Table of Contents

Advertisement

6.1.3.

IO-Link

Communication specification
Manufacturer ID
Device IDs
Bitrate
Minimum cycle time
SIO mode supported
Process data input length
IO-Link Revision
Required masterport class
Structure of process data input
The Process Data Input (the measured data of EE741) is configurable and structured in the following
order:
Bit no.
Process data input
Measurand index,
factory default
acc. to Tab. 11
Tab. 10
Scheme of process data input
Per factory default, the measurands' data type is FLOAT32 (more exactly, 32 bit single precision float). The
parameters may freely be selected via IO-Link device parameter, the most usual are pre-selected per default. See
Tab. 11 for the supported measurands.
Alternatively, the measured data may be represented as INT32 within the above scheme, the values are scaled
with a factor 1 000 in this case.
PLEASE NOTE
Please note that the data type selection (FLOAT32 or INT32) applies to the entire 12 byte process data
input, i.e., all 3 measureands will have the same data type at the same time.
Measurand description
Temperature
Standardized flow
Mass flow
Standardized volume flow
Consumption
Tab. 11
Indices of supported measurands
0563
EE741 DN15 to DN25 : 0x074111 475409 d
EE741 DN32 to DN50 : 0x074112 475409 d
COM2 (38.4 kBaud)
6.0 ms
no
12 bytes
1.1
A
95
64
Measurand 1
80
Mass flow m'
[kg/h]
Formula Sign
T
vn
m'
V'n
Qn
/ 1379
hex
dec
63
Measurand 2
83
Standardized volume
3
flow V'n [m
/h]
Unit
°C
°F
K
m/s
ft/min
kg/h
kg/min
kg/s
3
m
/h
3
m
/min
SLPM
l/s
SCFM
3
m
/s
3
m
3
ft
Inline Flow Sensor for Compressed Air and Gases | 24
User Manual EE741
32
31
Measurand 3
1
Temperature T
[°C]
Measurand Index
1
2
4
22
23
80
81
82
83
84
85
86
87
88
91
93