7.7 - MANUAL COOLING/ HEATING MODE
From board the machine
a. To activate/deactivate this function, keep cooling/heating selection key "T3" pressed
for 10 seconds until the blue and red symbols (A5) light up alternatively.
This setting is maintained also in the event of power interruption.
b. Pressing key "T3" for 2 seconds allows to cyclically select cooling (blue LED),
heating (red LED) or fan (red LED and blue LED off) mode.
From remote controller
a. To select this function, press the key "B2" until the heating only (D10) or cooling
only (D11) symbol appears on the remote controller.
From the remote controller it is not possible to change setting from manual mode to
automatic mode.
7.8 - FAN MODE
When this mode is used, the appliance does not exercise any action on temperature
or air humidity in the room, but only keeps it in circulation.
From board the machine
a. Pressing key "T3" for 2 seconds allows to cyclically select cooling (blue LED),
heating (red LED) or fan (red LED and blue LED off) mode.
b. Under this operating mode, the internal fan is always on and it is possible to select
the desired speed of the fan at any moment by pressing the specific key "T2".
The desired temperature which operates on the automatic speed
of the fan can be selected only from board the machine: the more
the desired temperature deviates from ambient temperature, the
more the fan speed is high.
These are the possible speeds for the fan.
MAXIMUM speed
MINIMUM speed
A
AUTO speed
Bi2 WALL TR 1000/1200/1400