Olimpia splendid Bi2 WALL TR 1000 Instructions For Use And Maintenance Manual page 81

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 49
From remote controller
a. To select this mode, press key "B11" until the indicator (D7) activates.
b. To be able to change ventilation speed, it is necessary to disable the function by
pressing key "B11" first.
When this function is enabled, the internal fan is controlled by the appliance automat-
ically and the set ambient temperature is automatically changed as follows:
decreased by 1°C after one hour and by another degree after 2 hours
in heating function;
increased by 1°C after one hour and by another degree after 2 hours in
cooling function.
7.10 - MEANING OF BLINKING AND OPERATION OF THE LED
- The blinking LED (A5) indicates that the request for water (hot or cold) has not
been met and causes the stop of the fan as long as water temperature does not
reach an appropriate value which can meet the request.
- The alternate switching on of the red and blue LEDs (A5) indicates that the auto-
matic cooling/heating mode is active.
- The 4 LEDs "
4 LEDs are off, Stand-by mode is active.
Each of these LEDs is active in blinking mode (soft-blinking) if during heating or
cooling (red or blue LEDs "A5" ON) the set temperature is respectively lower or
higher than the ambient temperature detected by the appliance.
To increase comfort at night, the LEDs brightness on the electronic
panel is decreased after 15 seconds of inactivity on the keys or on
the temperature selector.
Only from remote controller, press key "B7" to be able to switch off the LEDs on the
control panel after 15 seconds of inactivity on the keys.
Every time the keys are pressed on the control panel, the LEDs brightness returns at
maximum level over the following 15 seconds.
7.11 - SWING OPERATION
a. Press the key "B3", the icon (D9) lights up and the flap starts to oscillate. Press
key "B3" again, the icon (D9) switches off and the flap stops oscillation, stopping
in the position it reached at that moment.
A
", "
", "
" and "
" indicate the set fan speed. If all the
Bi2 WALL TR 1000/1200/1400
EN - 33