a. The appliance emits a low and continuous noise, like hissing, in cooling mode or when
stopping.
This noise is caused by operation of the drain pump (optional accessory).
b. The appliance emits a squealing noise, like a squeak, when the system stops after operation
in heating mode.
This noise is caused by the expansion and contraction of the plastic parts due to temperature
changes.
Dust escaping from the appliance
a. This occurs when the appliance is used for the first time after a long period of time and
depends on the accumulation of dust inside the appliance
The appliance gives off odours
a. The appliance can absorb the odour of rooms, furniture, cigarettes, etc. and return them
to the environment.
9.2 - INCONVENIENCES AND POSSIBLE REMEDIES
Consult the following points before requesting assistance or repairs.
MALFUNCTIONING
Ventilation activation is delayed
with respect to the new temperature
or function settings.
Ventilation speed increases or de-
creases automatically.
The appliance does not start ven-
tilation.
The fan does not activate even if
there is hot or cold water in the hy-
draulic circuit.
CAUSE
-
The circuit valve requires a
certain time for its opening and
therefore to make hot or cold
water circulate in the appliance.
-
The electronic control works so
as to adjust the best level of
comfort.
-
Hot or cold water is missing in
the system.
-
The hydraulic valve remains
closed.
-
The ventilation motor is locked
or burned out.
-
The electrical connections are
not correct.
WHAT MUST BE DONE?
-
Wait 2 or 3 minutes so that the
circuit valve opens.
-
Wait for temperature adjustment
or select silent function in case
of need.
-
Check that the boiler or the wa-
ter refrigerator are operational.
-
Dismount the valve body and
check if water circulation is
restored.
-
Check the operating status of
the valve by powering it sepa-
rately at 220 V. If it activates, the
problem may be in the electronic
control.
-
Check the motor windings and
the free rotation of the fan.
-
Check the electrical connec-
tions.