3.2.3 - Assembly of the fixing plate
BEFORE FIXING THE PLATE, MAKE SURE THAT THE WALL
WHERE THE APPLIANCE IS TO BE INSTALLED CAN SUPPORT
THE WEIGHT.
Operate as follows (fig. 7):
a.
Place the supplied drilling template (B) against the wall respecting the minimum
distances from the roof, from the floor and from the lateral walls; it is advised to
keep the template in correct position using adhesive tape (C).
b.
Mark the drilling points (9 points recommended).
The two holes (F) are prepared for wall fixing of the appliance.
c.
In the case of brick or concrete walls or similar, make 9 x 5 mm diameter holes.
d.
Insert the plugs (D) inside the holes (use suitable plugs on the basis of the type
of wall).
e.
Fix the plate (A) to the wall tightening all screws (E).
7
B
C
ø5mm
F
ø5mm
F
A
C
F
D
E
Bi2 WALL TR 1000/1200/1400
EN - 15