Features; Trademark - Mitsubishi Electric ME96SSRB-MB User Manual

Electronic multi-measuring instrument
Hide thumbs Also See for ME96SSRB-MB:
Table of Contents

Advertisement

Features

 The instrument measures load status by wiring the secondary sides of VT (Voltage Transformer) and CT
(Current Transformer) in the power receiving and distribution system and displays various measured values.
 The instrument supports Active Energy Class 0.5S and harmonic measurement (1st to 19th).
 Active energy can be measured by dividing into three time periods such as peak, off-peak, and shoulder.
(Periodic Active Energy)
 This instrument enables measurement of active energy/reactive energy/ apparent energy for any period
(interval). (Rolling demand active power/Rolling demand reactive power/Rolling demand apparent power)
 The password protection prevents undesired setting change and measured data deletion.
 The transmission function (MODBUS RTU communication, CC-Link communication, or MODBUS TCP
commination) transmits measured data to superior monitoring systems.
*CC-Link communication is available when ME-0040C-SS96 (optional plug-in module) is installed.
*MODBUS TCP commination is available when ME-0040C-SS96 (optional plug-in module) is installed.
 The logging function enables to back up measured values in a SD memory card even when a MODBUS RTU
communication error occurs.
*It is available when ME-0000BU-SS96 or ME-0000BU25-SS96 (optional plug-in module) is installed.
 This instrument itself can output key measuring elements such as current, voltage, active power, power
factor, and active energy at the power receiving point by installing an optional plug-in module with analog
output/pulse output function. It is ideal for remote monitoring.
*It is available when ME-4210-SS96B (optional plug-in module) is installed
 The built-in logging function provides the logging of measured values, alarm logs, and system logs into this
instrument.
 The standard complies with the requirements of CE marking, UL standards, KC mark, and FCC/IC.
 The support function for checking input wiring enables to determine the wiring condition in the test mode.
When either a voltage input or current input are incorrectly wired, the incorrect wiring part is displayed on the
screen and it also shows a current phase angle, a voltage phase angle, and each value of active power,
voltage, and current.

Trademark

MODBUS is a trademark of Schneider Electric USA Inc.
Ethernet is a trademark of FUJIFILM Business Innovation Corp.
SD Logo, SDHC logo are trademarks of SD-3C, LLC.
Other company and product names herein are trademarks or registered trademarks of their respective owners.
In the text, trademark symbols such as 'TM' and '®' may not be written.