I.

INTRODUCTION

The RST Rheometer is a rotational, controlled-stress rheometer used in quality control, product
development and research. The measuring drive developed for this instrument utilizes a high-precision
dynamic drive system with optical encoder for absolute position measurement of spindle deflection.
There are two basic methods of measurement available with the RST Rheometer:
Rotational measurement under controlled shear rate
Rotational measurement under controlled shear stress
The RST Rheometer has all the functionality of a standard Brookfield rotational viscometer, performing
rotational tests with pre-set speed or shear rate. The RST Rheometer is powerful for its additional ability
to perform tests with a pre-set torque or shear stress and measure the resulting shear deformation of the
test substance via angular deflection of the measuring element.
The RST Rheometer's unique controlled stress capabilities can be used for experiments such as the
precise measurement of the yield point of a test material without a need to shear the substance or the
measurement of creep behavior of a material and its recovery after shearing.
In addition, the RST Rheometer is equipped with a powerful motor with a usable torque range of 0.01 to
100 milli-Newton-meters. As a result, the RST Rheometer is appropriate for rheological measurements
over a wide range of test material viscosities.
The RST Rheometer has the following features of performance:
Digital control of rotational speed, shear rate, torque or shear stress
Pre-designed measurement programs for analysis of viscosity flow curves, creep and recovery
behavior, yield stress, and thixotropic properties
Automatic adjustment of control parameters during measurement
Direct indication of measured and calculated values of speed, shear rate, torque, shear stress,
viscosity, temperature, and time
Graphical display of measured results in real time
Internal storage of data including test parameters, measured values, and calculated values
User interface via touch screen display
Quick-connect coupling system for easy spindle attachment
Barcode reader for automatic spindle recognition
USB port for connection to printer, computer or USB flash drive
Serial interface (RS232-C) for connection to a computer
Operation in standalone mode via touch screen display or with a computer system running
Rheo3000 application software
DC power supplied by an AC/DC adapter
Standard delivery of the RST Rheometer includes the following:
Assembled RST Rheometer
AC/DC adapter and power cord
Operating Instructions
Certification of Test
Brookfield's Rheo3000 Software (30-day trial)
USB-RS232 Adapter
RS232 Cable
PC-USB Cable (A-B)