Table of Contents

Advertisement

Quick Links

IOM (Safety) -
Installation, Operation and Maintenance Manual
(Abridged, Safety-related part)
Optical Oxygen Analyzer (BOA)
For use with BOSx Optical Sensors
Optical O
Products (BOA)
2
ATEX / IEC / NEC / CEC

Advertisement

Table of Contents
loading

Summary of Contents for Ametek BARBEN ANALYTICAL OXY visor

  • Page 1 IOM (Safety) - Installation, Operation and Maintenance Manual (Abridged, Safety-related part) Optical Oxygen Analyzer (BOA) For use with BOSx Optical Sensors Optical O Products (BOA) ATEX / IEC / NEC / CEC...
  • Page 2: Table Of Contents

    Notice: This publication is for information only. The contents are subject to change without notice and should not be construed as a commitment, representation, warranty, or guarantee of any method, product, or device by Owner. Inquiries regarding this manual should be addressed to Ametek., Barben Analytical , Technical Support, at the following: Email: Sales.Barben@Ametek.com.
  • Page 3 Optical Oxygen Analyzer 2.8.1 - Product Label / Name Plate Overview ����������������������������������������������������������������������������������������������������������� 9 2.8.2 - Zone 1 Groups IIC - Barben Analytical | AMETEK ������������������������������������������������������������������������������������������ 10 2.8.3 - Zone 2 Groups IIC - Barben Analytical | AMETEK ������������������������������������������������������������������������������������������ 10 2.9 Declaration of Conformity - Certificate �������������������������������������������������������������������������������������������������11 Section 3 - Installation 3.1 Installation Overview ���������������������������������������������������������������������������������������������������������������������������12...
  • Page 4 IOM (Safety) - Installation, Operation and Maintenance Optical Oxygen Analyzer LIST OF TABLES LIST OF FIGURES LIST OF TABLES LIST OF FIGURES Table 1 - Technical Product Specification - Ratings Figure 1 - overview of hardware features OXYvisor OXYvisor Table 2 - Configuration - Product Model Selection Figure 2 - Overall Dimensions...
  • Page 5: Section 1 - General Information & Safety

    IOM (Safety) - Installation, Operation and Maintenance Optical Oxygen Analyzer Section 1 General Info & Safety Section 1 - General Information & Safety 1.1 Introduction - Purpose of this Manual The purpose of this abridged manual is to specifically inform the user of all the pertinent and required information, as it pertains to safety to install and operate this product.
  • Page 6: Safety Summary

    IOM (Safety) - Installation, Operation and Maintenance Section 1 Optical Oxygen Analyzer General Info & Safety 1.4 Safety Summary The OXYvisor is designed for use in manufacturing, industrial and laboratory analytical applications. The installer should consult national, local codes and any site specific installation requirements to ensure governing regulations are met. The OXYvisor goes through functional, performance and quality testing prior to leaving the factory.
  • Page 7: Section 2 - Technical Product Specifications - Ratings

    IOM (Safety) - Installation, Operation and Maintenance Optical Oxygen Analyzer Section 2 Technical Product Specification Section 2 - Technical Product Specifications - RATINGS 2�1 - BOA Oxygen Analyzer Specifications OXYvisor OXYvisor Oxygen Analyzer Specifications Power Supply - Selectable as AC or DC via Product Selection Nomenclature AC Power 85-240* VAC, 47-63 Hz, 6W (AC, “4-wire,”...
  • Page 8: General Principle Of Operation

    IOM (Safety) - Installation, Operation and Maintenance Section 2 Optical Oxygen Analyzer Technical Product Specification Additional Options for Product Model Selection (Table 2) * Sensor Style - Selection “X” can be: Sxyz, where xyz is equal to fiber length in meters (e.g. S025, S050) ** Mounting Orientation - Selection “Y”...
  • Page 9: Hazardous Area Agency Certification & Markings - [Recapitulation]

    IOM (Safety) - Installation, Operation and Maintenance Optical Oxygen Analyzer Section 2 Technical Product Specification 2.7 Hazardous Area Agency Certification & Markings - [Recapitulation] 2.7.1 Zone 1 Group IIC with Specific Conditions of Use OXYvisor is certified as Process Control Equipment for use in Zone Classified Hazardous Locations (QVAJ and QVAJ7) - Zone 1, Group IIC ATEX Zone 1, Group IIC Markings: II 2 G Ex db op is IIC T4 Gb...
  • Page 10: Zone 1 Groups Iic - Barben Analytical | Ametek

    Figure 3 - Product Label / Name Plate OXYvisor 2.8.2 - Zone 1 Groups IIC - Barben Analytical | AMETEK 0.865” 0.563” OXYvisor 5200 Convair Drive, Carson City NV 89706 - USA II 2 G Ex db op is IIC T4 Gb www.BarbenAnalytical.com...
  • Page 11: Declaration Of Conformity - Certificate

    Section 2 Technical Product Specification 2.9 Declaration of Conformity - Certificate Declaration of Conformity According to EN ISO/IEC 17050-1:2010 Manufacturer Name (Nom du Fabricant) Barben Analytical | AMETEK Address (Adresse) 5200 Convair Drive Carson City NV, 89706 USA Web: https://www.barbenanalytical.com We hereby declare under our sole responsibility that the following apparatus: (Nous déclarons par la présente sous notre seule responsabilité...
  • Page 12: Section 3 - Installation

    IOM (Safety) - Installation, Operation and Maintenance Section 3 Optical Oxygen Analyzer Installation Section 3 - Installation 3.1 Installation Overview The OXYvisor Optical Oxygen Analyzer includes a 316 SS pipe-mount bracket for field mounting. Additional components needed to produce a functional oxygen measurement include a Barben Oxygen Sensor (BOS) and Pt1000 RTD (Resistance Temperature Sensor).
  • Page 13: 3�5�3 Oxyvisor - Pipe-Mount To Horizontal Pipe

    IOM (Safety) - Installation, Operation and Maintenance Optical Oxygen Analyzer Section 3 Installation Vertical Pipe Install - FRONT VIEW VERTICAL PIPE MOUNT - TOP VIEW Back 316 SS Pipe Mount Bracket (4) 3/4” NPT or M25x 1.5 6H Conduit Ports (4) 316 SS M6 Slotted Screws OXYvisor...
  • Page 14: Dc Powered Analyzer

    IOM (Safety) - Installation, Operation and Maintenance Section 3 Optical Oxygen Analyzer Installation 3.6.3 DC Powered Analyzer Analyzer - Power Supply Connections (DC Version) The OXYvisor control unit can operate using 24 VDC +/-10%. When energized by mains the 24 V DC supply must be from a Class2 or LPS source, OR that a fuse (1 A) will be required in the installation.
  • Page 15: 3�8 Electrical Entries

    IOM (Safety) - Installation, Operation and Maintenance Optical Oxygen Analyzer Section 3 Installation 3�8 Electrical Entries Unused entries shall be closed with suitable certified Ex db blanking elements with a minimum IP66 rating CAUTION 3.9 Securing the Rear (Wiring) Compartment lid. After wiring the power and any input / output connections and before powering up the analyzer, the Rear (Wiring) Compartment lid should be installed and fully tightened.
  • Page 16: Hazardous Area - Installation & Control Drawings

    IOM (Safety) - Installation, Operation and Maintenance Section 3 Optical Oxygen Analyzer Installation 3.11 Hazardous Area - Installation & Control Drawings 3.11.1 Zone 1 - Group IIC - 2P0345 EXTERNAL PROTECTIVE TERMINAL CONDUCTOR TERMINAL COMPARTMENT DOOR NAMEPLATE: HAZARDOUS AREA RATINGS, MARKINGS, APPROVAL LABEL INSTALLATION &...
  • Page 17: Zone 2 - Group Iic - 2P0346

    IOM (Safety) - Installation, Operation and Maintenance Optical Oxygen Analyzer Section 3 Installation ZONE 1, GROUP IIC NON-HAZARDOUS AREA HAZARDOUS AREA REQUIRES PRODUCT MODEL SELECTION: AGENCY APPROVAL, "1." ENCLOSURE POWER SOURCE OXYvisor OPTICAL OXYGEN ANALYZER RS485, DIGITAL INPUTS, ANALOG OUTPUTS ZONE 1 UNIT FIBER OPTIC BUSHING...
  • Page 18: Figure 14.2 - Zone 2 Hazloc - Installation Control Dwg - 2P0346 (P.2)

    IOM (Safety) - Installation, Operation and Maintenance Section 3 Optical Oxygen Analyzer Installation INTERNAL PROTECTIVE CONDUCTOR TERMINAL COMMUNICATION, TRANSMITTER, RELAY, COMMUNICATION, TRANSMITTER, RELAY, AND CONTROL BLOCK WIRING AND CONTROL BLOCK WIRING REAR VIEW OF ENCLOSURE TERMINAL COMPARTMENT (DOOR REMOVED) POWER POWER INPUT INPUT...
  • Page 19: Class I, Div2 - 2P0335

    IOM (Safety) - Installation, Operation and Maintenance Optical Oxygen Analyzer Section 3 Installation 3.11.3 Class I, Div2 - 2P0335 EXTERNAL PROTECTIVE TERMINAL CONDUCTOR TERMINAL COMPARTMENT DOOR HAZARDOUS AREA APPROVAL LABEL LOCATION FIBER OPTIC BUSHING PORT ENCLOSURE O-RING SEALED REAR TERMINAL CONDUIT PORTS EXTERNAL PROTECTIVE CONDUCTOR TERMINAL...
  • Page 20: Figure 15.3 - Class I Div.2 Hazloc - Installation Control Dwg - 2P0335

    IOM (Safety) - Installation, Operation and Maintenance Section 3 Optical Oxygen Analyzer Installation CLASS I, DIVISION 2 NON-HAZARDOUS AREA HAZARDOUS AREA CLASS I, DIVISION 2 (REQUIRES DIVISION 2 HAZARDOUS AREA ORDERED OPTION) ENCLOSURE POWER SOURCE OXYvisor OPTICAL OXYGEN ANALYZER RS485, DIGITAL INPUTS, ANALOG OUTPUTS DIVISION 2 UNIT EXTERNAL POWER FOR...
  • Page 21: Section 4 - Operations

    IOM (Safety) - Installation, Operation and Maintenance Optical Oxygen Analyzer Section 4 Operations Section 4 - Operations 4.1 Operations Overview All programming of the OXYvisor analyzer can be accomplished either through the keypad or through the OXYvisor software provided with the unit.
  • Page 22 IOM (Safety) - Installation, Operation and Maintenance Section 4 Optical Oxygen Analyzer Operations Error X-type (critical) Error Description X-type (critical) Error Description Trouble shooting and things to check Trouble shooting and things to check Code Sensor signal is fully quenched. This is a common error when BOS3 sensors is exposed to ambient air, fix by running Sensor signal is fully quenched.
  • Page 23: Section 5- Maintenance / Repair / Service

    Danger of explosion in areas subject to explosion hazard. Connect the device correctly after maintenance. Close and seal the device after maintenance work. WARNING Technical Assistance is available directly from, Barben Analytical | AMETEK - 5200 Convair Drive, Carson City NV 89706 | +1.775.883.2500 | Sales. Barben@Ametek.com 5.2 Maintenance Overview The OXYvisor analyzer has minimal maintenance requirements.
  • Page 24 Loctite is a registered trademark of Loctite Corporation © 2021, by AMETEK, Inc. All rights reserved • 2111BA-IOM(safe) RevB • November 2021 USA • BELGIUM • CHINA • SINGAPORE Toll Free +1(800)993-9309 • Phone +1(775)883-2500 • Fax +1(775)883-6388 Sales.Barben@Ametek.com •...

Table of Contents