IN120 / IN220
FE6600/BL6600/MP6600 Series
Multi-point Lock
Installation Instructions
6
Installation Instructions (Continued)
i
Installation of Connectors
1. Snip the end of the packet to dispense the
grease. The supplied tube contains 5 grams
of grease (Fig. 8A).
2. Evenly distribute the grease over the
connector pins and contacts, wiping away
any excess (See Figure 8B). Do not overfill
or over apply. The full application requires
approximately 2.5 grams.
3 . Important: Do not run wires through the
bottom hole in the plate (See Figure 8B).
It will damage the wires and the controller
connector. Route wires around the flange.
Do not route wires through the flange hole.
4. Secure the 4-pin DPS connector (A).
See Figure 8C.
5. Secure the 10-pin lock body assembly
connector (B). See Figure 8C.
6. Tuck the excess cable into the wire hole on
the inside of the door.
7. Secure the mouting assembly while
ensuring proper alignment of the
outside reader and fully tighten the (2)
through-bolts on the inside of the door
to secure the reader and plate
to the door.
8. Secure the 24-pin card reader
connector (C). See Figure 8C.
9
Ensure all openings on the back of the
secured reader connector are covered
completely with grease (D).
See Figure 8D.
For installation assistance contact Corbin Russwin
1-800-543-3658 • techsupport.corbinrusswin@assaabloy.com
Copyright © 2019-2021 ASSA ABLOY Access and Egress Hardware Group, Inc. All rights reserved. Reproduction in whole
or in part without the express written permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
Do not touch or allow debris to enter connector contacts . Cover the
connectors with the silicone dielectric compound (grease) . See Figure 10A .
Fig. 8A
Fig. 8B
Fig. 8C
Fig. 8D
19