Assa Abloy Corbin Russwin IN120 Installation Instructions Manual page 11

Advertisement

IN120 / IN220
FE6600/BL6600/MP6600 Series
Multi-point Lock
Installation Instructions
5
IN220 (PoE) Wiring & Illustration, continued
c
PoE Door Harness
Order of installation may vary. Refer to appropriate sections for instructions.
Hinge-side harness connectors:
• 4-pin male Molex connector
• 6-pin male Molex connector with ground wire
Lock-side harness connectors:
• Ring terminal
• Male RJ45 connector (crimped after cable is fed through door)
Notes:
Connectors go on only one way. They cannot be plugged to incorrect position.
Do not force and do not offset connectors.
Be sure they are completely seated (flush).
d
PoE Lock
Order of installation may vary.
Refer to appropriate sections for instructions.
1. Prop door open
2. Using the ring terminal, carefully route the assembly
through the door channel toward lock.
Note: Do not terminate PoE harness (with RJ45 M)
until the cable has been routed through the door and
the inside mounting plate assembly. See Section 6J -
Installation of Connectors.
For installation assistance contact Corbin Russwin
1-800-543-3658 • techsupport.corbinrusswin@assaabloy.com
Copyright © 2019-2021 ASSA ABLOY Access and Egress Hardware Group, Inc. All rights reserved. Reproduction in whole
or in part without the express written permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
IN220 PoE Lock
11
FM455 04/21

Advertisement