Download Print this page

Assa Abloy Corbin Russwin IN120 Installation Instructions Manual page 18

Advertisement

IN120 / IN220
FE6600/BL6600/MP6600 Series
Multi-point Lock
Installation Instructions
6
Installation Instructions (Continued)
h
Outside Reader Installation, continued
4. Next feed the cables/connectors through the inside mounting assembly (and gasket if required*).
5. Secure the mounting assembly while ensuring proper alignment of outside reader and tighten
the (2) through-bolts on the inside of the door to secure the reader (See figure below).
IMPORTANT: Do not run wires through bottom hole in plate. It will damage wires and the controller
connector. Route wires around flange, do not route wires through the flange hole
(See figure detail below).
6. Secure ground lug(s) with #6-32 machine screw.
*Gasket is required for outdoor installations.
If installing with gasket; separate gasket from mounting plate to feed cables/connectors through holes
as indicated.
Once cables/connectors are fed through, reattach gasket to mounting plate.
For installation assistance contact Corbin Russwin
1-800-543-3658 • techsupport.corbinrusswin@assaabloy.com
Copyright © 2019-2021 ASSA ABLOY Access and Egress Hardware Group, Inc. All rights reserved. Reproduction in whole
or in part without the express written permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
Fig. 7
18
FM455 04/21

Advertisement

loading

This manual is also suitable for:

Corbin russwin in220