Status
Code
03-371
The control logic sensed that the IOT PWB detected a data mismatch
Initial action:
Switch off the machine power.
If there is other equipment close by that may be generating electrical noise or radio frequency interference,
power it off also.
Clean and inspect all corotrons for defects and ensure they are properly installed.
Power the machine on.
If the problem still exists:
Place a service call.
03-600
The control logic sensed a Billing Data Recovery Failure.
Initial action:
Switch off the machine power.
If there is other equipment close by that may be generating electrical noise or radio frequency interference,
power it off also.
Contact Building Maintenance and have them verify the proper voltage at the machine plug.
Clean and inspect all corotrons for defects and ensure they are properly installed Section 5-Repairs.
Power the machine on.
If the problem still exists:
Place a service call.
Fault Code Procedures
Description/Direction
5/98
2-8
5750 DocuCare Service Manual