Status
Code
10-366, 367
The control logic sensed that the Heat Roll temperature exceeded 180˚.
Initial action:
Check the Heat Roll Control Thermistor for cleanliness, damage and excessive wear at the point where the
Thermistor contacts the Heat Roll (REP 5.37).
If the problem still exists:
Place a service call.
10-368
The control logic sensed an open circuit from the Pressure Roll control thermistor.
Initial action:
Check the Pressure Roll Control Thermistor for cleanliness, damage and excessive wear at the point where
the Thermistor contacts the Pressure Roll (REP 5.37).
If the problem still exists:
Place a service call.
10-369
The control logic sensed an open circuit from the Pressure Roll overheat thermistor.
Initial action:
Check the Pressure Roll Control Thermistor for cleanliness, damage and excessive wear at the point where
the Thermistor contacts the Pressure Roll (REP 5.37).
If the problem still exists:
Place a service call.