10-360
The control logic sensed an open circuit from the Heat Roll Overheat Thermistor.
Initial action:
Check the Heat Roll Overheat Thermistor for cleanliness, damage and excessive wear at the point where
the Thermistor contacts the Heat Roll (REP 5.37).
If the problem still exists:
Place a service call.
10-361
The control logic sensed that the Heat Roll did not reach operating temperature.
Initial action:
Ensure that the Heat Roll surface is clean and not damaged (REP 5.31).
Check the Heat Roll Control Thermistor for cleanliness, damage and excessive wear at the point where the
Thermistor contacts the Heat Roll (REP 5.37).
If the problem still exists:
Place a service call.
10-362
The control logic sensed that the Heat Rod did not turn off after the Heat Roll reached operating temperature.
Initial action:
Ensure that the Heat Roll surface is clean (no debris, paper, etc.) (REP 5.31)
Check the Heat Roll Control Thermistor for cleanliness, damage and excessive wear at the point where the
Thermistor contacts the Heat Roll (REP 5.37).
If the problem still exists:
Place a service call.