Xerox 5750 Service Manual page 16

Docucare service manual fault code procedures
Hide thumbs Also See for 5750:

Advertisement

Status
Code
06-340, 359
The control logic sensed an error in the self test routines of the IISS PWB Ram test (06-340), or the IISS PWB ROM
test (06-359).
Initial action:
Switch off the machine power.
If there is other equipment close by that may be generating electrical noise or radio frequency interference,
power it off also.
Contact Building Maintenance and have them verify the proper voltage at the machine plug.
Clean and inspect all corotrons for defects and ensure they are properly installed Section 5-Repairs.
Power the machine on.
If the problem still exists:
Place a service call.
06-361
The control logic sensed a fault with the Scan Carraige Registration Sensor.
Initial action:
Switch off the machine power.
Verify that the IIT (Image Input Terminal) Registration Sensor is correctly aligned and free from contamina-
tion.
Power the machine on.
If the problem still exists:
Place a service call.
Fault Code Procedures
Description/Direction
5/98