Pin Signals - Digi XBee-PRO 900 Instruction Manual

Oem rf modules
Table of Contents

Advertisement

XBee‐PRO® 900  OEM RF Modules  

Pin Signals

Pin #
1
2
3
DIN / CONFIG
4
5
6
PWM0 / RSSI / DIO10
7
8
9
DTR / SLEEP_RQ/ DIO8
10
11
12
13
14
15
Associate / DIO5/AD5
16
17
18
19
20
Downloaded from
Elcodis.com
electronic components distributor
XBee‐PRO® 900  RF Module Pin Number
(top sides shown ‐ shields on bottom)
Pin Assignments for the XBee‐PRO® 900  Modules
(Low‐asserted signals are distinguished with a horizontal line above signal name.)
Name
Direction
Vcc
-
DOUT
Output
Input
DIO12
Either
Input/Open drain
RESET
output
Either
PWM / DIO11
Either
[reserved]
-
Either
GND
-
DIO4/AD4
Either
CTS / DIO7
Either
ON / SLEEP
Output
Vref
-
Either
RTS / DIO6
Either
AD3 / DIO3
Either
AD2 / DIO2
Either
AD1 / DIO1
Either
AD0 / DIO0
Either
Design Notes:
• Minimum connections: VCC, GND, DOUT & DIN
• Minimum connections to support serial firmware upgrades: VCC, GND, DIN, DOUT, RTS & DTR
• Signal Direction is specified with respect to the module
• Module includes an internal 5K Ohm resistor to RESET
• Several of the input pull-ups can be configured using the PR command
• Unused pins should be left disconnected
To ensure proper power up, Vcc SLOPE must be superior or equal to 6V/ms.
© 2008 Digi International, Inc.
Description
Power supply
UART Data Out
UART Data In
Digital I/O 12
Module Reset (reset pulse must be at least 100 us. This must
be driven as a open drain/collector. The module will drive this
line low when a reset occurs. This line should never be driven
high.)
PWM Output 0 / RX Signal Strength Indicator / Digital IO
Digital I/O 11
Do not connect
Pin Sleep Control Line or Digital IO 8
Ground
Digital I/O 4
Clear-to-Send Flow Control or Digital I/O 7
Module Status Indicator or Digital I/O 9
This line must be connected if AD sampling is desired. Must be
between 2.6 V and Vcc.
Associated Indicator, Digital I/O 5
Request-to-Send Flow Control, Digital I/O
Analog Input 3 or Digital I/O 3
Analog Input 2 or Digital I/O 2
Analog Input 1 or Digital I/O 1
Analog Input 0, Digital I/O 0
Max Voltage
3.6V
Vcc
5V
Vcc
Vcc
Vcc
Vcc
n/a
5V
0V
Vcc
Vcc
Vcc
Vcc
Vcc
5V
Vcc
Vcc
Vcc
Vcc
     7