Install the DC Power Cables
B
0.31 in. (0.78
cm)
M
0.81 in. (2 cm)
To attach the DC power supplies:
1. Locate the terminal block plug.
2. Insert the DC-input power source wires into the terminal block plug.
3. Attach the DC supply wires using the designated screws.
4. Use a ratcheting torque screwdriver to torque the terminal block plug captive screw. (See the following
figure.)
Figure 25: Attach the DC Power Supply Wires
Activate a DC Power Supply Module
Perform the following procedure to activate a DC power supply:
1. Verify the power supply operation by checking whether the respective power supply front panel LED
(PS0 or PS1) is green.
2. If the LEDs indicate any issues with power problem, see Appendix.
3. If you are also connecting a redundant DC power supply, repeat these steps for the second power source.
Note
If you are connecting a redundant DC power supply, ensure that each power supply is connected to a separate
power source in order to prevent power loss in the event of a power failure.