Cisco 8011-2X2XP4L Hardware Installation Manual page 61

Ple service endpoint router
Table of Contents

Advertisement

Configure the Device
Displays information about the field replaceable units (FRUs), including product IDs, serial numbers, and
version IDs.
Example:
#show inventory
2. show environment
Displays all environment-related router information.
Example:
# show environment
3. show environment temperature
Displays temperature readings for on-board temperature sensors and for PSU. Each temperature sensor
has three thresholds:
4. show environment power
Displays the power usage information for the entire router.
Example:
#show environment power
5. show environment voltage
Displays the voltage for the entire router.
Example:
#show environment voltage
6. show environment current
• Minor temperature threshold: When a minor threshold is exceeded, a minor alarm occurs and the
following actions occur for all sensors:
• System messages are displayed
• SNMP notifications (if configured) are sent
• Log environmental alarm event is triggered (Run the show alarm command to review this.)
• Major temperature threshold: When a major threshold is exceeded, a major alarm occurs and the
following actions occur for all sensors:
• System messages are displayed
• SNMP notifications (if configured) are sent
• Log environmental alarm event is triggered (Run the show alarm command to review this.)
• Critical temperature threshold: When a critical threshold is exceeded, a critical alarm occurs and the
following actions occurs:
• For all the main board sensors the system is shut down.
• For the PSU sensor, the particular PSU is turned off .