Scope Of Delivery; Choice Of Location & Setup - Bresser SCIENCE TRM-301 Instruction Manual

Trinocular transmitted light microscope
Hide thumbs Also See for SCIENCE TRM-301:
Table of Contents

Advertisement

Available languages

Available languages

accessories and tools in a place inaccessible to children!
• Keep chemicals and liquids out of reach of children! Don't drink! Clean hands thoroughly under running water after use.
In case of accidental contact with eyes or mouth, rinse with water. In case of complaints, consult a doctor immediately and
show the substances.
THIS DEVICE GENERATES HEAT!
This device contains a halogen light source (12V/30W). Halogen lamps emit a considerable amount of infrared light as heat.
As a result, the surface of the lamp housing becomes very hot. Leave sufficient space around the microscope and DO NOT
place it near flammable materials. Important: The heat generated can also cause the specimens to warm up! Adjust the
brightness to your requirements: Set the Koehler illumination on the microscope by illuminating only the part of the sample
that you want to inspect. Switch off the light when you are not using the microscope.
DANGER OF PROPERTY DAMAGE!
Improper handling can cause DAMAGE to the device and/or the accessories! Therefore, use the device only in accordance
with the following safety information.
• Do not disassemble the device! In case of a defect, contact your dealer. The dealer will contact the service centre and send
the device for repair if necessary.
• Do not expose the device to high temperatures and protect it from water and high humidity!
• Do not subject the device to shocks!
• Only use accessories and spare parts that comply with the technical specifications!

2. SCOPE OF DELIVERY

A
A: Transmitted light microscope
B: 2 pcs. Eyepieces (WF 10x)
C: 4 pcs. Lenses (4x, 10x, 40x, 100x oil / pre-assembled)
D: Coaxial XY stage with vernier adjustment (pre-assembled)
3. CHOICE OF LOCATION & SETUP
Before setting up your microscope, choose a suitable location.
Place the microscope on a surface that meets the following criteria:
• Flat/level
• Vibration-free/stable
• Hard, non-combustible surface
• Chemically and mechanically resistant
Set up the microscope so that ...
• ... the ventilation slots on the back are not blocked.
• ... there is a distance of at least 10 cm around the device or to other appliances or the wall.
• ... you can disconnect it from the power supply at any time.
ATTENTION! Always use the supplied power adapter (12V, 4A) for the halogen light (12V/30W) and dimmer. Using an
unsuitable power supply unit can cause damage to the microscope!
16
16
B
C
E: Power adapter (12V, 4A)
F: Blue colour filter disc
G: Immersion oil
H: Dust cover
D
F
G
E
H