5. Ratings/Specifications

The  in the model names indicate the protective heights in millimeters.
Type 4
Type of ESPE (IEC
61496-1)
Type 2
Performance
Object Resolution (Detection Capability)
Beam Gap
Number of Beams
Lens Size
Protective Height
Long
Operating Range
Short
ON to OFF
OFF to ON
Response Time
*1. Response time when used in one segment system or in cascaded connection.
*2. Selectable by Configuration Tool.
Effective Aperture
Type 4
Angle (EAA) (IEC
Type 2
61496-2)
Light Source
Startup Waiting Time
Electrical
Power Supply Voltage (Vs)
Current Consumption
Safety Outputs (OSSD)
Output Operation
Safety Output
Mode
F3SG-RE
Quick Installation Manual
F3SG-4RE14
F3SG-2RE14
F3SG-4RE14/30
F3SG-2RE14/30
Opaque objects
14-mm dia.
10 mm
15 to 207
5.2 × 3.4 (W × H) mm
160 to 2080 mm (6.3 to 81.9 inch)
0.3 to 10.0 m (1 to 32 ft.)
0.3 to 3.0 m (1 to 10 ft.)
5 to 15 ms
25 to 75 ms
Refer to F3SG-R Series User's Manual for more information.
±2.5° max., emitter and receiver at operating range of 3 m or greater
±5.0° max., emitter and receiver at operating range of 3 m or greater
Infrared LEDs, Wavelength: 870 nm
2 s max.
SELV/PELV 24 VDC±20% (ripple p-p 10% max.)
Refer to F3SG-R Series User's Manual.
F3SG-REP: Two PNP transistor outputs
F3SG-REN: Two NPN transistor outputs
Load current of 300 mA max., Residual voltage of 2 V max. (except for voltage drop due
to cable extension), Capacitive load of 1 F max., Inductive load of 2.2 H max. *1
Leakage current of 1 mA max. (PNP), 2 mA max. (NPN) *2
*1. The load inductance is the maximum value when the safety output frequently repeats
ON and OFF. When you use the safety output at 4 Hz or less, the usable load
inductance becomes larger.
*2. These values must be taken into consideration when connecting elements including
a capacitive load such as a capacitor.
Light-ON (Safety output is enabled when the receiver receives an emitting signal.)
F3SG-4RE30
F3SG-2RE30
30-mm dia.
20 mm
8 to 124
7-mm dia.
190 to 2510 mm (7.3 to 98.7 inch)
0.3 to 20.0 m (1 to 65 ft.)
0.3 to 7.0 m (1 to 23 ft.)
6

Advertisement

Table of Contents
loading

This manual is also suitable for:

F3sg-4re 14F3sg-2re 14F3sg-4re 30F3sg-2re 30Z352-e1

Table of Contents