Omron F3SG RE Series Quick Installation Manual page 14

Safety light curtain
Hide thumbs Also See for F3SG RE Series:
Table of Contents

Advertisement

Possible Circumventing by Reaching Over the Detection Zone
If access to the hazardous zone by reaching over the detection zone of vertically mounted F3SG-R cannot be
excluded, the height and the safety distance, S, of the F3SG-R shall be determined. S shall be determined by
comparison of the calculated values in Detection Zone Orthogonal to Direction of Approach . The greater
value resulting from this comparison shall be applied.
S=(K × T) + Cro . . . Formula (5)
• S: Safety distance
• K: Approach speed to the detection zone
• T: Total response time of the machine and F3SG-R
• Cro: Approach distance based on the distance which personnel
can move towards the hazardous zone of a machine by reaching
over the detection zone. The distance is determined in the table
below based on the height of the hazardous zone, a, and the
height of the upper edge of the detection zone, b.
Note:Lower edge of the detection zone above 300 mm in relation to the reference
plane does not offer sufficient protection against crawling below.
First, use K = 2,000 mm/s in formula (5) for the calculation. If the
result of this calculation is less than 100 mm, use S = 100 mm.
If the result exceeds 500 mm, use K = 1,600 mm/s to recalculate it. If
the result of the recalculation is less than 500 mm, use S = 500 mm.
Height of
hazardous
900
zone, a
2600
0
2500
400
2400
550
2200
800
2000
950
1800
1100
1600
1150
1400
1200
1200
1200
1000
1200
800
1150
600
1050
400
900
200
600
0
0
Note 1.Upper edge of the detection zone below 900 mm is not included since they do not offer sufficient protection against
circumventing or stepping over.
Note 2.When determining the values of this table, it shall not be interpolated. If the known values a, b or Cro are between two values of
this table, the greater safety distance shall be used.
[Calculation example]
• T: Tm + Ts (s)
• Tm: Machine's response time (s)
• Ts: Response time of the F3SG-R from ON to OFF (s)
• a: Height of machine hazardous zone (mm)
• b: Height of upper edge of detection zone (mm)
13
Height of upper edge of detection zone, b
1000
1100
1200
Additional distance to hazardous zone, Cro
0
0
0
400
350
300
550
550
500
750
750
700
950
850
850
1100
950
950
1150
1100
1000
1200
1100
1000
1200
1100
1000
1150
1050
950
1050
950
800
950
750
550
700
0
0
0
0
0
0
0
0
1300
1400
1600
0
0
0
300
300
300
450
450
400
650
650
600
800
750
700
850
800
750
900
850
750
900
850
650
850
800
0
750
700
0
500
450
0
0
0
0
0
0
0
0
0
0
0
0
0
Safety
distance (S)
Hazard
b
a
300 mm max.
Reference plane
1800
2000
2200
0
0
0
300
250
150
400
300
250
550
400
250
550
400
0
550
0
0
450
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Quick Installation Manual
2400
2600
0
0
100
0
100
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0