Page 4
F3S-B Introduction Thank you for purchasing the F3S-B series Safety Light Curtain. Always heed the following points when using the F3S-B: • Make sure that personnel operating the F3S-B are knowledgeable about the machine on which it is installed • Read this manual completely and be sure you understand the information provided before attempting to operate the F3S-B •...
Page 5
F3S-B WARNING The F3S-B is a TYPE 2 Electro-sensitive protective equipment, intended to be used as or with the safety related part of control system to category 2,1, or B as defined in the European standard EN954-1. Do not use the F3S-B in category 3 or 4 systems. Do not use the F3S-B on machines that cannot be stopped by electrical control in case of an emergency.
Page 6
F3S-B Notice For your safety, always pay attention to the following: Installation Environment • Do not install the F3S-B in the following environments: − Areas exposed to intense interference light such as direct sunlight. − Areas with high-humidity where condensation is likely to occur. −...
Page 7
F3S-B PRIOR TO USE Make sure the following items were supplied with each F3S-B, contact your nearest OMRON representative or distributor if any item is missing. • F3S-B unit (emitter qty. 1, receiver qty. 1) • Mounting brackets (top and bottom) qty. 4...
F3S-B DESCRIPTION Section 1 1-1 Basics 1-2 Features • Self-test WARNING • Optical resolution of 30, 55 or 80 mm in diame- Use the F3S-B only in category 2, 1, or B appli- cations as defined in pr EN 1050 or EN 954-1. •...
F3S-B External Test > 15 ms If your application requires periodic testing more often than every 2 seconds an external control External test system is able to initiate an external test with the input (open) External test function. If a signal of 17 VDC to Vs is applied to the External test input at least 15 ms, Approx.
F3S-B 1-5 Detection zone Protective height The F3S-B can detect in the area indicated by “Protective height” in the figure below. The protective height is from “the Optical-axis line mark above the indicator area” to “the end of the yellow metal case”. Optical-axis line mark The center line for optical axes is indicated by the triangle mark.
F3S-B 1-6-2 Series connection types When your application requires an additional pro- tective zone, for example, to prevent someone from staying behind a primary detection zone, the F3S-B may be connected in series. The system consists of a master unit, a slave unit, and a series connection cable, type F39-JB1B (refer to “2-3-2 Wiring diagram”...
F3S-B 1-7 Ratings and Performance Type F3S-B P (*1) F3S-BM (*1) F3S-BS (*1) Stand-alone Master unit for series Slave unit for series Item connection connection No. of optical axes 12 to 66 6 to 33 4 to 22 12 to 66 6 to 33 4 to 22 12 to 30 6 to 15 4 to10 Optical-axis pitch...
F3S-B Type F3S-B P (*1) F3S-BM (*1) F3S-BS (*1) Stand-alone Master unit for series Slave unit for series Item connection connection Degree of IEC60529 IP65 protection Vibration Normal operation : 10 to 55 Hz, double-amplitude: 0.7mm, X, Y and Z directions resistance 20 sweeps Shock resistance...
F3S-B 1-9 Table of Types Type Naming Rule F3S - B M 36 2 P 12 - L blank $ Stand-alone $ Master unit for series connection $ Slave unit for series connection $ No. of optical axis (4-66) $ 25mm optical pitch $ 50mm optical pitch $ 75mm optical pitch blank $ Slave unit...
F3S-B WIRING and MOUNTING Section 2 2-1 Installation Conditions WARNING Do not use the F3S-B on machines that can not be stopped by electrical control in case of an emer- gency. Do not use the F3S-B in flammable or explosive environments. 2-1-1 Detection Zone and Intrusion Path WARNING Install protective structures around a machine so that you must pass through the detection zone to reach...
Page 18
F3S-B Using EN 999 Formula (See Note 1) Safety distance is calculated based on the following equation. S = K x T + C S : Safety distance K : Intrusion speed into the detection zone T : Total response time for the machine and light curtain C : Additional distance calculated or defined based on the optical resolution of the light curtain When safety distance is not provided by European standards for individual machine, the distance can be calculated using EN 999.
Page 19
F3S-B Using ANSI/RIA R15.06 Formula (See Note 4) Safety distance is calculated based on the following equation when a person moves perpendicular to the detection zone of a light curtain. S = K x ( Ts + Tc + Tr ) + Dpf S : Safety Distance (mm) K : Speed constant of 1,600 mm/s (63 inches/s) minimum based on the movement being the hand/arm only and the body being stationary.
F3S-B 2-1-3 Distance from Reflective Surfaces WARNING Be sure to install the F3S-B to minimize the effects of reflection from reflective surfaces. Failure to do so will cause detection to fail and may result in serious injury. Install the F3S-B with minimum Distance D shown below from reflective surfaces (highly reflective sur- faces) like metal walls, floors, ceilings, and work pieces.
Page 21
F3S-B Correct installations are shown below to prevent mutual interference. • Alternate emitters and receivers (Correct) (Correct) RS-485 RS-485 RS-485 (Correct) Emitter 1 Receiver 1 Emitter 2 Receiver 2 RS-485 • Install barriers (Correct) RS-485 RS-485 • Keep enough distance between each set of sensors Arrange the sets so that distance between their protective height marks is greater than “D”...
Page 24
F3S-B • Rear Mounting (without Intermediate Mounting Bracket) MOUNTING BRACKET 50.3 (TOP AND BOTTOM) 4-MOUNTING HOLES 40.3 OPTICAL AXIS M12 CONNECTOR (note 2, 3) 4-M5 MOUNTING SCREW HOLES Unit: mm Type Protective Full length of Full length Mounting hole height the sensor with brackets center width...
Page 25
F3S-B Note: 1. The intermediate bracket and mounting screw holes are only applied to types which have a protective height of 1050 mm or longer. 2. The master unit has an M12 connector on both ends of the sensor (for the extension cable and the se- ries connection cable).
F3S-B 2-2-2 Mounting Bracket (Top and Bottom) R2.75 R1.75 R4.5 Unit: mm 2-2-3 Mounting Plate Only supplied with types which have a protective height of 1050 mm or longer. The mounting plates are only required when the F3S-B is mounted in the rear mounting configuration with the intermediate brackets.
F3S-B 2-2-4 Mounting Bracket (Intermediate) Only supplied with types which have a protective height of 1050 mm or longer. MOUNTING SCREW FOR SENSOR (M6x8) FLAT INTERMEDIATE BRACKET RUBBER U-SHAPED INTERMEDIATE BRACKET FIXING SCREW FOR BRACKET (M4x10) L-SHAPED INTERMEDIATE BRACKET Unit: mm Configuration of U-shaped Intermediate Bracket Mounted at 90 Degree Angle How to use L-shaped intermediate bracket...
Standard for Class 2 and Class 3 Transformers, UL 1585. Recommended power supply: S82K (15 W, 30 W, 50 W, 90 W type) made by OMRON, UL Listed (UL508, Class2 Output) and CE Marked (EMC and Low Voltage Directives) Power supply and loads must be reinforced insulated or double insulated as shown in the following figure to protect against electrical shock.
F3S-B 2-3-2 Wiring Diagram Disconnect all sources of power before wiring the F3S-B to a machine. Emitter Receiver RS-485(A) (Grey 5) RS-485(B) (Pink 6) Load E1: 24 VDC Power supply S1: External test switch K1, K2: Relay or PLC input to control the dangerous movement of a machine Load: Inductive load with surge suppressor (Note) or resistive load to indicate unstable condition When using Start/restart interlock Function When using optional Relay Monitoring Function...
F3S-B 2-3-3 Wiring Procedure 1. Connect the emitter extension cable (F39-JB A-L optional, gray color outer jacket) to the emitter. (The emitter uses gray color plastic caps.) 2. Connect the receiver extension cable (F39-JB A-D optional, black color outer jacket) to the receiver. (The receiver unit uses black color plastic caps.) 3.
F3S-B ADJUSTMENT Section 3 3-1 Adjustment Procedure 1. Ensure the following points. • A hazardous part of a machine cannot move during the adjustment. • The optical surfaces of the emitter and receiver are clean. • There should be no light-interrupting objects in the F3S-B detection zone. 2.
Page 32
F3S-B 9. % When two or more units are used in close proximity, they are mounted properly to prevent mutual interference. Turn ON power to the F3S-B and make sure the F3S-B is operating properly as described below with the machine stopped. 10.
F3S-B APPLICATIONS Section 5 5-1 Application (1) 5-2 Application (2) without Start/restart interlock function with Start/restart interlock function without Relay monitoring function with Relay monitoring function Emitter Receiver Emitter Receiver RS-485(A) RS-485(A) RS-485(B) RS-485(B) KM1 KM2 KM1 KM2 M: 3-phase motor M: 3-phase motor E1: 24 VDC Power supply E1: 24 VDC Power supply...
F3S-B MAINTENANCE Section 6 WARNING Do not use the F3S-B until the following inspections are completed. Failure to do so may result in loss of life or serious injury. Do not disassemble, repair or modify the F3S-B. Note: 1. For Safety, be sure to record and store inspection results. 2.
F3S-B TROUBLESHOOTING Section 8 The F3S-B runs internal self-tests after the power is turned ON and while the F3S-B is in normal opera- tion. The external test is also available. If a failure is detected, a corresponding flicker pattern is indicated by the red LED (OFF-state indicator) of the receiver.
Page 38
Industrial Sensors Division Sensing Devices and Components Div. H.Q. Shiokoji horikawa Shimogyo-ku, Kyoto 600-8530 JAPAN Tel: +81-75-344-7068 / Fax: +81-75-344-7107 OMRON EUROPE SENSOR BU Carl-Benz-Str.4 71154 Nufringen GERMANY Tel: +49-7032-811-0 / Fax: +49-7032-811-199 OMRON ELECTRONICS, INC. 1 East Commerce Drive, Schaumburg, IL 60173 Authorised Distributor: U.S.A.