Ratings; Ratings/Specifications - Omron F3SJ-A P Series User Manual

Hide thumbs Also See for F3SJ-A P Series:
Table of Contents

Advertisement

Ratings

Ratings/Specifications

In the model names in this table, the
Detection capability
Beam gap
Number of beams
Protective height
Lens diameter
Operating range
Response time
Startup waiting time
Power supply voltage
Current consumption (no
Emitter
load)
Receiver
Light source
Effective aperture angle (EAA)
Safety outputs(OSSD)
Auxiliary output 1 (Non-safety output)
External indicator output (Non-safety
output)
Output operation mode
Input voltage
Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : info@audin.fr
contain the 4 digits indicating the protective height (mm).
F3SJ-A
P14
Opaque objects
Diameter 14mm
9mm
26 to 234
245 to 2,117mm
Diameter 5mm
0.2 to 9m (for protective height up to 1649 mm)
0.2 to 7m (for protective height 1655 mm or greater)
ON to OFF: 10ms to 27.5ms max., OFF to ON: 40ms to 110ms max. (when incidence is
stable).
Refer to p.14 for details.
2s max. (2.2s max in case of series connection)
24VDC ± 20% (ripple p-p10% max.)
Up to 50 beams: 78 mA max., 51 to 100 beams: 113 mA max., 101 to 150 beams: 140 mA
max., 151 to 200 beams: 163 mA max., 201 to 234 beams: 177 mA max.
Up to 50 beams: 66 mA max., 51 to 100 beams: 83 mA max., 101 to 150 beams: 101 mA
max., 151 to 200 beams: 118 mA max., 201 to 234 beams: 130 mA max.
Infrared LED (870nm wavelength)
Within ±2.5 ° for the emitter and receiver at a detection distance of at least 3 m according to
IEC61496-2
PNP transistor outputs x 2, Load current 300mA max, Residual voltage 2V max. (except for
voltage drop due to cable extension), Maximum capacity load 2.2
max. (This may be different from previously used logic (ON/OFF) because safety circuit is
used.)
PNP transistor output x 1, Load current 300mA max., Residual voltage 2V max. (except for
voltage drop due to cable extension), Maximum capacity load 2.2
max.
Connectable external indicator
- Incandescent lamp : 24VDC, 3 to 7W
- LED lamp : Load current 300mA max.
Maximum capacity load 2.2
(An indicator cable F39-JJ3N or F39-A01P -PAC is required when using an external
indicator.)
Safety outputs : ON when receiving light
Auxiliary output 1 : Reverse output of safety output
External indicator output 1: Reverse output of safety output (for basic system), ON during
muting/override (for muting system)
External indicator output 2: ON in lockout (for basic system), ON during muting/override (for
muting system)
Test input, interlock selection input, reset input, external relay monitoring input, and inputs
input are all performed at the voltages below:
ON voltage: 9 to 24V (sink current 3mA max.)
OFF voltage: 0 to 1.5V, or open
AUDIN - 8, avenue de la malle - 51370 Saint Brice Courcelles
Overview and Specifications
F3SJ-A
P20
Opaque objects
Diameter 20mm
15mm
16 to 166
245 to 2,495mm
µ
F, Leakage current 1mA max.
F3SJ-A
P30
Opaque objects
Diameter 30mm
25mm
10 to 100
245 to 2,495mm
µ
F, leakage current 1 mA
µ
F, leakage current 1mA
F3SJ-A
User's Manual