Janome JR3000 Series Operation Manual page 112

Hide thumbs Also See for JR3000 Series:
Table of Contents

Advertisement

■ Safety Circuit
Power
switch
AC200-240V
L
50-60Hz
N
From Inlet
P.C.B. B
Software
EMG
IO-S
Disable
Power ON
Signal
24V
3.3V
External Control (I/O / Fieldbus)
P.C.B. RY
CNAC1
24V
CNDCIN
5V
24V
RY2
5V
RY1
24V
RY1
RY2
CNB
CNRY
111
PS1
CNAC2
L
24V
N
0V
Fuse
CNOUTL
CNX
DVX
CNY
DVY
CNZ
DVZ
CNR
DVR
24V
SWITCH BOX
Emergency
CNSB
switch
TEACHING PENDANT
Emergency
CNTP
switch
Detect IO-S
CNIOS
Detect EMG
Detect Power ON
DESKTOP ROBOT JR3000
Outlet
MX
MY
MZ
MR
I/O-S

Advertisement

Table of Contents
loading

Table of Contents